8.Place a handle (311) on a valve stem (302) at the vertical, or near vertical, spray position.

9.Apply blue threadlock on the nut (304) threads and tighten the handle against the spring (320) and clip (318). Torque to 70-80 in.-lbs. (7.9-9 N•m).

10.Place the rod (312) and the second handle (311) on second valve stem aligned with the opposite handle.

11.Repeat step 9.

12.Install two screws (313) in handles (311).

13.Check operation of the handle and valves.

14.Operate the handle in and out of the spray and cir- culate positions.

15.Check for clearance with fittings.

NOTE:

Both valves should settle firmly into the spray position inward against the seats in the valve.

Both valve stems should rotate out to their most extended positions when the handle is pulled down to the circulate position.

3A0420H