Setup
Setup
Reference numbers and letters in paren-
theses in the text refer to numbers and letters in the illustrations.
Connecting Air Line
1.Install an air pressure regulator on gun air supply line to control air pressure.
2.Install a shutoff valve downstream of the air regulator to shut off gun air.
3.Connect a clean, dry, filtered air supply to air inlet fitting (13). Connect other end to shutoff valve.
Connecting Fluid Supply
Pressure feed guns:
1.To control fluid pressure to the gun, install a fluid regulator on the fluid line.
2.Connect the fluid hose
to the gun fluid inlet,
3.Connect other end to a regulated fluid supply line.
Gravity feed guns:
1.Install fluid filter (24) into fluid inlet (A).
2.Screw on gravity cup.
3.Remove gravity cup cover and fill cup with solvent to flush if this is first time using equipment. (See Flushing, page 6.)
4.After flushing, fill cup with fluid and attach cover.
A
1
5
13
4 | 312388K |