![](/images/new-backgrounds/1328762/32876255x1.webp)
Performance Charts
Aluminum Husky 3275 Air Consumption
AIR CONSUMPTION––scfm (cubic meters/min)
350
(9.8)
300
(8.4)
250
(7.0)
200
(5.6)
150
(4.2)
100
(2.8)
50
(1.4)
0
0
Test Conditions: Pump tested in water with inlet submerged.
Air Consumption Curves
A at 120 psi (0.8 MPa, 8 bar) air pressure
B at 100 psi (0.7 MPa, 7 bar) air pressure
C at 70 psi (0.48 MPa, 4.8 bar) air pressure
Dat 40 psi (0.28 MPa, 2.8 bar) air pressure
Eat 20 psi (0.14 MPa, 1.4 bar) air pressure
A
B
C
D
E
30 | 60 | 90 | 120 | 150 | 180 | 210 | 240 | 270 |
(114) | (227) | (341) | (454) | (568) | (681) | (795) | (908) | (1022) |
FLUID
To find Pump Air Consumption (scfm or m#/min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):
1.Locate fluid flow rate along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve.
3.Follow left to scale to read air consumption.
28 308639