Performance Charts

Aluminum Husky 3275 Air Consumption

AIR CONSUMPTION––scfm (cubic meters/min)

350

(9.8)

300

(8.4)

250

(7.0)

200

(5.6)

150

(4.2)

100

(2.8)

50

(1.4)

0

0

Test Conditions: Pump tested in water with inlet submerged.

Air Consumption Curves

A at 120 psi (0.8 MPa, 8 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

Dat 40 psi (0.28 MPa, 2.8 bar) air pressure

Eat 20 psi (0.14 MPa, 1.4 bar) air pressure

A

B

C

D

E

30

60

90

120

150

180

210

240

270

(114)

(227)

(341)

(454)

(568)

(681)

(795)

(908)

(1022)

FLUID FLOW––gpm (lpm)

To find Pump Air Consumption (scfm or m#/min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):

1.Locate fluid flow rate along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve.

3.Follow left to scale to read air consumption.

28 308639

Page 28
Image 28
Graco Inc 308639L important safety instructions AIR CONSUMPTION--scfm cubic meters/min, Air Consumption Curves