How the Air-Assisted Spray Gun Operates
The
The
The spray gun has a
Operation
2.Trigger the gun to check the atomization; do not be concerned about the pattern shape yet.
3.Slowly increase the fluid pressure, just to the point where a further increase in fluid pressure does not significantly improve fluid atomization.
4.Close off the pattern adjustment air by turning the knob clockwise (in) all the way. See FIG. 14. This sets the gun for its widest pattern.
CLOSE
OPEN
TI6559A
FIG. 14
Spray Pattern Adjustment
SKIN INJECTION HAZARD
To reduce the risk of component rupture and serious injury, including injection, do not exceed the gun’s maximum fluid working pressure or the maximum working pressure of the lowest rated component in the system.
1.Do not turn on the gun air supply yet. Set the fluid pressure at a low starting pressure. If a fluid pres- sure regulator is installed, use it to make adjust- ments.
If your system does not have a fluid regulator, the fluid pressure is controlled by the air regulator sup- plying the pump, per the formula below:
Pump x Pump Air Regulator Setting = | Fluid |
Ratio | Pressure |
5.Set the atomizing air pressure at about 5 psi (0.35 bar, 35 kPa) when triggered. Check the spray pat- tern, then slowly increase the air pressure until the tails are completely atomized and pulled into the spray pattern. See FIG. 15. Do not exceed 100 psi (0.7 MPa, 7 bar) air pressure to the gun.
For a narrower pattern, turn the pattern adjustment valve knob counterclockwise (out). See FIG. 14. If the pattern is still not narrow enough, increase the air pressure to the gun slightly or use a different size tip. (Not available for RAC tip guns.)
| TI0792A |
no air | too little air correct amount |
| of air |
FIG. 15
311001C | 11 |