Troubleshooting
SKIN INJECTION HAZARD
Follow Pressure Relief Procedure on page 10. Read warnings, page 4.
Troubleshooting
• Check all possible remedies in the trouble- shooting charts before disassembling the gun.
•Some improper patterns are caused by the improper balance between air and fluid.
General Troubleshooting
Problem | Cause | Solution |
|
|
|
|
|
|
Fluid leakage from back of fluid | Worn packings or needle shaft. | Replace needle assembly (2). |
packing area. |
|
|
|
|
|
Air leakage from gun. | Air valve not seating properly. | Clean or replace air valve (8). |
|
|
|
Fluid leakage from front of gun. | Needle ball worn or damaged. | Replace needle assembly (2) and seat (5c). |
|
|
|
| Worn seat assembly. | Replace the seat (5c) and gasket (5b, model |
|
| G40 gun only). The gasket must be replaced |
|
| whenever the seat assembly is removed. |
|
|
|
| Fluid viscosity too low for proper | Install acetal seat (5c). |
| seal with carbide seat. |
|
|
|
|
Fluid in air passages. | Spray tip seal leaking. | Tighten retaining ring (6) or replace spray tip |
|
| (33). |
| Leaking around seat housing. | Replace the gasket (5b, model G40 gun |
|
| only). The gasket must be replaced whenever |
|
| the seat assembly is removed. |
|
|
|
| Fluid inlet fitting leaking. | Replace the fluid tube gasket (22). The gas- |
|
| ket must be replaced whenever the fluid tube |
|
| connector is removed. |
|
|
|
Slow fluid | Fluid buildup on fluid needle | Remove and clean or replace the fluid needle |
| components. | assembly (2). |
|
|
|
No fluid output when triggered. | Spray tip plugged. | Clean spray tip. See page 14. |
|
|
|
| Fluid filter or fluid hose plugged. | After tip removal (see above), very slowly |
|
| loosen the hose end coupling at the gun and |
|
| relieve pressure gradually. Then loosen com- |
|
| pletely to clear the obstruction. Clean or |
|
| replace filter (12). |