Graco Inc 311001C important safety instructions Typical Installation Grounding

Models: 311001C

1 36
Download 36 pages 15.16 Kb
Page 6
Image 6

Installation

Installation

Typical Installation

Grounding

The typical installation shown in FIG. 1 is only a guide for selecting and installing air-assisted spray systems. Con- tact your Graco distributor for assistance in designing a system to meet your needs.

VENTILATE THE SPRAY BOOTH

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Do not operate the spray gun unless ventilation fans are operating.

Check and follow all of the National, State, and Local codes regarding air exhaust velocity requirements.

Check and follow all local safety and fire codes.

Check your local electrical code and pump manual for detailed grounding instructions. Use only electrically conductive fluid hoses.

Ground the spray gun through connection to a prop- erly grounded fluid supply hose and pump.

D

B

E

AG

C

TI6554A

FIG. 1: Typical Installation (Model G15 Shown)

 

F

 

 

 

 

 

Key:

 

 

A

Air Line Filter

E

Spray Gun

B

Air Shutoff Valve

F

Electrically Conductive Fluid Hose

C

Gun Air Pressure Regulator

G

Gun Air Supply Hose

D

Air Line

 

 

6

311001C

Page 6
Image 6