Graco Inc 311001C RAC SwitchTips, for use with AA Series Air Cap, LTX RAC Spray Tips

Models: 311001C

1 36
Download 36 pages 15.16 Kb
Page 31
Image 31

Spray Tip Selection Chart

RAC SwitchTips, for use with AA Series Air Cap

All tips in the Spray Tip Selection Charts below can be used with Model 249238 G40 guns equipped with RAC air cap 249478.

LTX RAC Spray Tips

Order desired tip (Part No. LTXxxx) from matrix below.

Tips are sometimes packaged with other promo- tional parts intended for the airless market. Disre- gard extra parts.

 

* Fluid Output, fl oz/min (lpm)

 

 

Maximum Pattern Width at 12 in. (305 mm)

 

 

Orifice Size in.

 

 

 

 

 

 

 

 

 

 

at 2000 psi

2 to 4

4 to 6

6 to 8

8 to 10

10 to 12

12 to 14

14 to 16

16 to 18

18 to 20

(mm)

(14.0 MPa, 140 bar)

(100)

(150)

(200)

(250)

(300)

(350)

(400)

(450)

(500)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.009 (0.229)

11.2 (0.33)

 

209

309

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.011 (0.279)

16.6 (0.49)

 

211

311

411

511

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.013 (0.330)

23.3 (0.69)

 

213

313

413

513

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.015 (0.381)

30.8 (0.91)

 

215

315

415

515

615

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.017 (0.432)

39.5 (1.17)

 

217

317

417

517

617

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.019 (0.483)

49.7 (1.47)

 

219

319

419

519

619

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.021 (0.533)

60.5 (1.79)

 

 

321

421

521

621

721

 

 

 

 

 

 

 

 

 

 

 

 

 

0.023 (0.584)

72.7 (2.15)

 

 

 

423

523

623

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.025 (0.635)

85.9 (2.54)

 

 

 

 

525

625

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.027 (0.686)

100.0 (2.96)

 

 

 

 

527

627

 

827

 

 

 

 

 

 

 

 

 

 

 

 

0.029 (0.737)

115.6 (3.42)

 

 

 

 

 

629

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.031 (0.787)

131.8 (3.90)

 

 

 

 

531

631

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.033 (0.838)

149.4 (4.42)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.035 (0.889)

 

 

 

 

 

535

635

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Tips are tested in water.

Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) P where QT = fluid output (fl oz/min) from the above table for the selected orifice size.

Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.

311001C

31

Page 31
Image 31
Graco Inc 311001C important safety instructions RAC SwitchTips, for use with AA Series Air Cap, LTX RAC Spray Tips