Installation

Installation

Typical Installation

NOTE: The typical installation shown in FIG. 1 is only a guide for selecting and installing air-assisted spray sys- tems. Contact your Graco distributor for assistance in designing a system to meet your needs.

Ventilate the Spray Booth

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Do not operate the spray gun unless ventilation fans are operating.

Check and follow all of the National, State, and Local codes regarding air exhaust velocity requirements.

Check and follow all local safety and fire codes.

Grounding

Check your local electrical code and pump man- ual for detailed grounding instructions. Use only electrically conductive fluid hoses.

Ground the spray gun through connection to a properly grounded fluid supply hose and pump.

E

D

AG

C

B

TI6554A

F

FIG. 1: Typical Installation (Model G15 Shown)

Key:

AAir Line Filter

BAir Shutoff Valve

CGun Air Pressure Regulator

DAir Line

ESpray Gun

FElectrically Conductive Fluid Hose

GGun Air Supply Hose

6

3A0149C

Page 6
Image 6
Graco Inc 3A0149C important safety instructions Typical Installation Ventilate the Spray Booth, Grounding