GXV3601 IP Camera

than 15V, this will damage the IP camera.

Internally, the Alarm-out uses relays as a switch (30VAC/2A); users can connect devices such as alarm siren or alert light to this port. Under normal circumstances, the circuit is open. When there is an alarm event, the GXV3601 will close the circuit to trigger the alarm.

Connect Alarm Input Equipment to the GXV3601

Here are two sample connection diagrams. Connect the alarm equipment to the GXV3601 by following the diagram below.

Set up Alarm Actions

An alarm action is what the GXV3601 is going to do when an alarm is triggered during the defined time period – the time schedule. The GXV3601 allows multiple alarm actions.

Record Video – If this option is selected, the GXV3601 will record the video when an alarm is triggered. You can enter the length of the video recording (in seconds). You can also choose the storage method for video

Firmware 1.0.4.6

Page 28 of 36

Grandstream Networks, Inc.

09/2010

Page 28
Image 28