6.17.10 Cumulative operation time alarm setting

H : Cumulative operation time alarm setting

Function

This parameter allows you to set the inverter so that it will put out an alarm signal after a lapse of the cumulative operation time set with H.

*"0.1" displayed on the monitor refers to 10 hours, and therefore "1" denotes 100 hours. Ex.: 38.5 displayed on the monitor = 3850 (hours)

Title

Function

 

Adjustment range

Default setting

H

Cumulative operation time

0.0-999.9

 

610.0

 

alarm setting

 

 

 

Setting of output signal l

Ex.: When assigning the cumulative operation alarm signal output function to the RY-RC terminals

Title

Function

 

Adjustment range

Setting value

 

6

H

Output terminal selection 1A

0-255

 

42 (negative

 

 

(RY-RC)

 

 

logic 43)

 

 

6.17.11 Over-voltage stall protection level

H : Over-voltage stall protection level

For more details, see section 6.12.4.

F-63