6.3Terminal function selection
6.3.1Keeping an input terminal function always active (ON)
H :
H :
•Function
This parameter specifies an input terminal function that is always to be kept active (ON).
[Parameter setting]
Title | Function | Adjustment range | Default setting | |
H | 0 (No function) | |||
|
|
|
|
|
H | 1 (Standby) | |||
|
|
|
|
|
* Coast stop
The standard default setting is for deceleration stop. To make a coast stop, assign a "1(ST)" terminal function to an idle terminal using the programmable terminal function.
Change to H=.
For coast stop, OFF the ST terminal when stopping the motor in the state described at left.The monitor on the inverter at this time will display QHH.
Motor | Coast stop | 6 |
| ||
speed |
| |
F terminal |
| ON |
| OFF | |
|
| |
ST terminal |
| ON |
| OFF | |
|
|
6.3.2Modifying input terminal functions
H : Input terminal selection 1 (F)
H : Input terminal selection 2 (R)
H : Input terminal selection 3 (RES)
H : Input terminal selection 8 (VIA)