Table of output terminal functions 1

Function

Code

Function

Action

 

 

No.

 

 

 

 

 

0

LL

Frequency lower limit

ON: The output frequency is above the NN set

 

 

 

 

 

value.

 

 

 

 

 

OFF: The output frequency is equal to or less than

 

 

 

 

 

the NN set value.

 

 

1

LLN

Inversion of frequency lower limit

Inversion of LL setting

 

 

2

UL

Frequency upper limit

ON: Output frequency is equal to or higher than

 

 

 

 

 

WN value.

 

 

 

 

 

OFF: Output frequency is lower than WN value.

 

 

3

ULN

Inversion of frequency upper limit

Inversion of UL setting

 

 

4

LOW

Low-speed detection signal

ON: Output frequency is equal to or higher than

 

 

 

 

 

H value.

 

 

 

 

 

OFF: Output frequency is lower than H

 

 

 

 

 

value.

 

 

5

LOWN

Inversion of low-speed detection signal

Inversion of LOW setting

 

 

6

RCH

Designated frequency attainment signal

ON: The output frequency is equal to or less than

 

 

 

 

(completion of acceleration/deceleration)

the specified frequency ± frequency set with

 

 

 

 

 

H.

 

 

 

 

 

OFF: The output frequency is above the specified

 

 

 

 

 

frequency ± frequency set with H.

 

 

7

RCHN

Inversion of designated frequency attainment

Inversion of RCH setting

 

 

 

 

signal (inversion of completion of

 

 

 

 

 

acceleration/deceleration)

 

 

 

8

RCHF

Set frequency attainment signal

ON: The output frequency is equal to or less than

 

 

 

 

 

the frequency set with H ± H.

 

 

 

 

 

OFF: The output frequency is above the frequency

 

 

 

 

 

set with H ± H.

 

 

9

RCHFN

Inversion of set frequency attainment signal

Inversion of RCHF setting

 

 

10

FL

Failure signal (trip output)

ON: When inverter is tripped

 

 

 

 

 

OFF: When inverter is not tripped

 

 

11

FLN

Inversion of failure signal (inversion of trip output)

Inversion of FL setting

 

 

12

OT

Over-torque detection

ON: Torque current is equal to or larger than

 

 

 

 

 

H set value and longer than H

 

 

 

 

 

set time.

 

 

 

 

 

OFF: The torque current is equal to or less than

 

 

 

 

 

(H set value - H set value).

 

 

13

OTN

Inversion of over-torque detection

Inversion of OT

 

 

14

RUN

Start/Stop

ON: When operation frequency is output or during

 

 

 

 

 

(FD)

 

 

 

 

 

OFF: Operation stopped

 

 

15

RUNN

Inversion of RUN/STOP

Inversion of RUN setting

 

 

16

POL

OL pre-alarm

ON: 50% or more of calculated value of overload

 

 

 

 

 

protection level

 

 

 

 

 

OFF: Less than 50% of calculated value of

 

 

 

 

 

11

 

 

 

overload protection level

 

17

POLN

Inversion of OL pre-alarm

Inversion of POL setting

 

 

20

POT

Over-torque detection pre-alarm

ON: Torque current is equal to or larger than 70%

 

 

 

 

 

 

of H set value.

 

 

 

 

 

OFF: The torque current is below (H set

 

 

 

 

 

value x 70% - H set value).

 

 

21

POTN

Inversion of over-torque detection pre-alarm

Inversion of POT setting

 

 

22

PAL

Pre-alarm

One of the following is turned on:

 

 

 

 

 

ON POL, POT, MOFF, UC, OT, LL stop, COT,

 

 

 

 

 

and instantaneous power failure coast stop.

 

 

 

 

 

or E,R,J issues an alarm

 

 

 

 

 

All the following are turned off:

 

 

 

 

 

OFF POL, POT, MOFF, UC, OT, LL stop,

 

 

 

 

 

COT, and instantaneous power failure coast

 

 

 

 

 

stop.

 

 

 

 

 

or E,R,J issues no alarm

 

 

K-17