E6581381
■Table of output terminal functions 2
|
| Function | Code | Function | Action | |
|
| No. | ||||
|
|
|
|
| ||
|
| 23 | PALN | Inversion of | Inversion of PAL setting | |
|
| 24 | UC | ON: The output current is equal to or less than | ||
|
|
|
|
| H set value for H set time. | |
|
|
|
|
| OFF: The output current is equal to or larger than | |
|
|
|
|
| H set value + 10%. | |
|
| 25 | UCN | Inversion of | Inversion of UC setting | |
|
| 26 | HFL | Significant failure | ON: QEC,QEN,QV,G, | |
|
|
|
|
| GGR,GVP,GRJQ,GTT- | |
|
|
|
|
| ,QJ,WR,GH,WE, | |
|
|
|
|
| GV[R,GRJ) | |
|
|
|
|
| OFF: Failure other than the above | |
|
| 27 | HFLN | Inversion of significant failure | Inversion of HFL setting | |
|
| 28 | LFL | Insignificant failure | ON: | |
|
|
|
|
| OFF: Failure other than the above | |
|
| 29 | LFLN | Inversion of insignificant failure | Inversion of LFL setting | |
|
| 30 | RDY1 | Ready for operation (including ST/RUN) | ON: Ready for operation (ST and RUN are also | |
|
|
|
|
| ON) | |
|
|
|
|
| OFF: Others | |
|
| 31 | RDY1N | Inversion of ready for operation (including | Inversion of RDY1 setting | |
|
|
|
| ST/RUN) |
| |
|
| 32 | RDY2 | Ready for operation (excluding ST/RUN) | ON: Ready for operation (ST and RUN are not | |
|
|
|
|
| ON) | |
|
|
|
|
| OFF: Others | |
|
| 33 | RDY2N | Inversion of ready for operation (excluding ST/RUN) | Inversion of RDY2 | |
|
| 34 | FCVIB | Frequency VIB selection | ON: VIB selected as frequency command | |
|
|
|
|
| OFF: Terminal other than VIB selected as | |
|
|
|
|
| frequency command | |
|
| 35 | FCVIBN | Inversion of frequency VIB selection | Inversion of FCVIB | |
|
| 36 | FLR | Fault signal (put out also at the time of a retry) | ON: When inverter trips or retries | |
|
|
|
|
| OFF: When inverter does not trip or retry | |
|
| 37 | FLRN | Inversion of failure signal (put out also at the time | Inversion of FLR | |
|
|
|
| of a retry) |
| |
|
| 38 | OUT0 | Specified data output 1 | ON: Specified data from remote control FA50: | |
|
|
|
|
| BIT0= 1 | |
|
|
|
|
| OFF: Specified data from remote control FA50: | |
|
|
|
|
| BIT0= 0 | |
|
| 39 | OUT0N | Inversion of specified data output 1 | Inversion of OUT0 setting | |
|
| 42 | COT | Cumulative operation time alarm | ON: Cumulative operation time is equal to or | |
|
|
|
|
| longer than H | |
|
|
|
|
| OFF: Cumulative operation time is shorter than | |
|
|
|
|
| H | |
|
| 43 | COTN | Inversion of cumulative operation time alarm | Inversion of COT | |
|
| 44 | LTA | Parts replacement alarm | ON: Calculation for parts replacement time is | |
11 | ||||||
|
|
|
| equal to or longer than the preset time | ||
|
|
|
|
| ON: Calculation for parts replancement time is | |
|
|
|
|
| shorter than the preset time | |
|
|
|
|
| ||
|
| 45 | LTAN | Inversion of replacement alarm | Inversion of LTA | |
|
| 48 | LI1 | F terminal input signal | ON: The signal input to F terminal is ON | |
|
|
|
|
| OFF: The signal input to F terminal is OFF | |
|
| 49 | LI1N | Inversion of F terminal input signal | Inversion of LI1 | |
|
| 50 | LI2 | R terminal input signal | ON: The signal input to R terminal is ON | |
|
|
|
|
| OFF: The signal input to R terminal is OFF | |
|
| 51 | LI2N | Inversion of R terminal input signal | Inversion of LI2 | |
|
| 52 | PIDF | Signal in accordance of frequency command (VIA) | ON: Frequency commanded by HOQF or | |
|
|
|
|
| H and that by VIA show the same | |
|
|
|
|
| value. | |
|
|
|
|
| OFF: Frequency commanded by HOQF or | |
|
|
|
|
| H and that by VIA show different | |
|
|
|
|
| values. |