E6581381

Table of output terminal functions 2

 

 

Function

Code

Function

Action

 

 

No.

 

 

 

 

 

 

 

23

PALN

Inversion of pre-alarm

Inversion of PAL setting

 

 

24

UC

Small-current detection

ON: The output current is equal to or less than

 

 

 

 

 

H set value for H set time.

 

 

 

 

 

OFF: The output current is equal to or larger than

 

 

 

 

 

H set value + 10%.

 

 

25

UCN

Inversion of small-current detection

Inversion of UC setting

 

 

26

HFL

Significant failure

ON: QEC,QEN,QV,G,

 

 

 

 

 

GGR,GVP,GRJQ,GTT-

 

 

 

 

 

,QJ,WR,GH,WE,

 

 

 

 

 

GV[R,GRJ)

 

 

 

 

 

OFF: Failure other than the above

 

 

27

HFLN

Inversion of significant failure

Inversion of HFL setting

 

 

28

LFL

Insignificant failure

ON: (QE-,QR-,QJ,QN-)

 

 

 

 

 

OFF: Failure other than the above

 

 

29

LFLN

Inversion of insignificant failure

Inversion of LFL setting

 

 

30

RDY1

Ready for operation (including ST/RUN)

ON: Ready for operation (ST and RUN are also

 

 

 

 

 

ON)

 

 

 

 

 

OFF: Others

 

 

31

RDY1N

Inversion of ready for operation (including

Inversion of RDY1 setting

 

 

 

 

ST/RUN)

 

 

 

32

RDY2

Ready for operation (excluding ST/RUN)

ON: Ready for operation (ST and RUN are not

 

 

 

 

 

ON)

 

 

 

 

 

OFF: Others

 

 

33

RDY2N

Inversion of ready for operation (excluding ST/RUN)

Inversion of RDY2

 

 

34

FCVIB

Frequency VIB selection

ON: VIB selected as frequency command

 

 

 

 

 

OFF: Terminal other than VIB selected as

 

 

 

 

 

frequency command

 

 

35

FCVIBN

Inversion of frequency VIB selection

Inversion of FCVIB

 

 

36

FLR

Fault signal (put out also at the time of a retry)

ON: When inverter trips or retries

 

 

 

 

 

OFF: When inverter does not trip or retry

 

 

37

FLRN

Inversion of failure signal (put out also at the time

Inversion of FLR

 

 

 

 

of a retry)

 

 

 

38

OUT0

Specified data output 1

ON: Specified data from remote control FA50:

 

 

 

 

 

BIT0= 1

 

 

 

 

 

OFF: Specified data from remote control FA50:

 

 

 

 

 

BIT0= 0

 

 

39

OUT0N

Inversion of specified data output 1

Inversion of OUT0 setting

 

 

42

COT

Cumulative operation time alarm

ON: Cumulative operation time is equal to or

 

 

 

 

 

longer than H

 

 

 

 

 

OFF: Cumulative operation time is shorter than

 

 

 

 

 

H

 

 

43

COTN

Inversion of cumulative operation time alarm

Inversion of COT

 

 

44

LTA

Parts replacement alarm

ON: Calculation for parts replacement time is

11

 

 

 

 

equal to or longer than the preset time

 

 

 

 

 

ON: Calculation for parts replancement time is

 

 

 

 

 

shorter than the preset time

 

 

 

 

 

 

 

45

LTAN

Inversion of replacement alarm

Inversion of LTA

 

 

48

LI1

F terminal input signal

ON: The signal input to F terminal is ON

 

 

 

 

 

OFF: The signal input to F terminal is OFF

 

 

49

LI1N

Inversion of F terminal input signal

Inversion of LI1

 

 

50

LI2

R terminal input signal

ON: The signal input to R terminal is ON

 

 

 

 

 

OFF: The signal input to R terminal is OFF

 

 

51

LI2N

Inversion of R terminal input signal

Inversion of LI2

 

 

52

PIDF

Signal in accordance of frequency command (VIA)

ON: Frequency commanded by HOQF or

 

 

 

 

 

H and that by VIA show the same

 

 

 

 

 

value.

 

 

 

 

 

OFF: Frequency commanded by HOQF or

 

 

 

 

 

H and that by VIA show different

 

 

 

 

 

values.

K-18

Page 226