E6581381

6.5.2Setting frequency command characteristics

6

+

H : VIA input point 1 setting

H : VIA input point 1 frequency

H : VIA input point 2 setting

H : VIA input point 2 frequency

H : VIB input point 1 setting

H : VIB input point 1 frequency

H : VIB input point 2 setting

H : VIB input point 2 frequency

H : Communication command point 1 setting

H : Communication command point 1 frequency

H : Communication command point 2 setting

H : Communication command point 2 frequency

Function

These parameters adjust the output frequency according to the externally applied analog signal (0- 10Vdc voltage, 4-20mAdc current) and the entered command for setting an external contact frequency.

To fine adjust the frequency command characteristics for VIA/VIB input, use the parameters H to H. See section 6.5.4.

F-16

Page 112
Image 112
Toshiba VF-FS1 instruction manual Setting frequency command characteristics