Toshiba VF-FS1 Selection of operation panel stop pattern, Display of the head of the parameters

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 172
Image 172

E6581381

6.20.6 Selection of operation panel stop pattern

H : Selection of operation panel stop pattern

Function

This parameter are used to select a mode in which the motor started by pressing the RUN key on the operation panel is stopped when the STOP key is pressed.

1)Slowdown stop

The motor slows down to a stop in the deceleration time set with FGE (or H).

2)Coast stop

The inverter cuts off power supply to the motor. The motor comes to a stop after coasting for a while by inertia. Depending on the load, the motor may keep running for a good long time.

 

 

[Parameter setting]

 

 

 

 

Title

Function

Adjustment range

Default setting

 

 

H

Selection of operation panel stop

0: Slowdown stop

0

 

 

 

pattern

1: Coast stop

 

6

6.20.7 Display of the head of the parameters

 

 

 

H : Head of the parameter display selection

Function

The parameter can be set at the front of the setting monitor mode.

If selecting “1:CWJ”, the Wizard parameter “CWH” is not displayed.

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Head of parameter display

0: AUF

0

 

selection

1: AUH

 

6.20.8 Integral output power

H : Integral output power retention selection

H : Integral output power display unit selection

Function

At the main power off ,it is selectable whether retention of integral output power values or not.

And also, the display unit is selectable.

F-76

Page 172
Image 172
Toshiba VF-FS1 Selection of operation panel stop pattern, Display of the head of the parameters, Integral output power