14. Inspection and maintenance

Danger

The equipment must be inspected every day.

If the equipment is not inspected and maintained, errors and malfunctions may not be discovered which could lead to accidents.

Before inspection, perform the following steps.

(1) Shut off all input power to the inverter.

Mandatory

(2)

Wait at least ten minutes and check to make sure that the charge lamp is no longer lit.

(3)

Use a tester that can measure DC voltages (800V DC or more), and check that the voltage to the

 

 

 

DC main circuits (across PA/+ and PC/-) does not exceed 45V.

 

Performing an inspection without carrying out these steps first could lead to electric shock.

Be sure to inspect the inverter regularly and periodically to prevent it from breaking down because of the environment of use, such as temperature, humidity, dust and vibration, or deterioration of its components with aging.

14.1 Regular inspection

Since electronic parts are susceptible to heat, install the inverter in a cool, well-ventilated and dust-free place. This is essential for increasing the service life.

The purpose of regular inspections is to maintain the correct environment of use and to find any sign of failure or malfunction by comparing current operation data with past operation records.

Subject of

Inspection procedure

Criteria for judgement

inspection

Inspection item

Inspection

Inspection method

cycle

 

 

 

 

 

 

1)Dust, temperature

Occasionally

1)Visual check, check

1)Improve the environment if

 

and gas

 

by means of a

it is found to be

 

 

 

thermometer, smell

unfavorable.

1. Indoor

 

 

check

 

environment

2)Drop of water or

Occasionally

2)Visual check

2)Check for any trace of

 

other liquid

 

 

water condensation.

 

3)Room temperature

Occasionally

3)Check by means of

3)Max. temperature: 60°C

 

 

 

a thermometer

 

 

 

 

 

 

 

 

Is something unusual is

 

 

 

 

found, open the door and

2. Units and

1)Vibration and noise

Occasionally

Tactile check of the

check the transformer,

reactors, contactors, relays,

components

cabinet

 

 

cooling fan, etc., inside. If

 

 

 

 

 

 

 

 

necessary, stop the

 

 

 

 

operation.

 

1)Load current

Occasionally

Moving-iron type AC

To be within the rated

3. Operation

 

 

ammeter

current, voltage and

2)Voltage (*)

Occasionally

Rectifier type AC

temperature.

data

 

 

voltmeter

No significant difference

(output side)

 

 

3) Temperature

Occasionally

Thermometer

from data collected in a

 

 

 

 

 

normal state.

*) The voltage measured may slightly vary from voltmeter to voltmeter. When measuring the voltage,

always take readings from the same circuit tester or voltmeter.

 