Toshiba VF-FS1 When retry function is selected inverter, Maintenance and inspection

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 7
Image 7

 

 

 

 

E6581381

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

Warning

See item

 

 

 

Observe all permissible operating ranges of motors and mechanical equipment. (Refer to 3. the motor's instruction manual.)

Not observing these ranges may result in injury.

Prohibited

When sequence for restart after a momentary failure is selected (inverter)

 

 

 

 

 

 

 

 

 

 

 

Warning

See item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stand clear of motors and mechanical equipment.

6.12.1

 

 

 

 

 

 

 

 

 

If the motor stops due to a momentary power failure, the equipment will start suddenly

 

 

 

 

 

 

after power recovers. This could result in unexpected injury.

 

Mandatory

Attach warnings about sudden restart after a momentary power failure on inverters,

6.12.1

 

motors and equipment for prevention of accidents in advance.

 

 

 

 

 

 

 

When retry function is selected (inverter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

See item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stand clear of motors and equipment.

6.12.3

 

 

 

 

 

If the motor and equipment stop when the alarm is given, selection of the retry function will

 

 

 

 

 

 

 

 

 

 

 

 

restart them suddenly after the specified time has elapsed. This could result in

 

 

 

 

 

 

unexpected injury.

 

Mandatory

 

 

Attach warnings about sudden restart in retry function on inverters, motors and equipment

6.12.3

 

 

 

 

 

for prevention of accidents in advance.

 

Maintenance and inspection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Danger

See item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not replace parts.

14.2

 

 

 

 

 

This could be a cause of electric shock, fire and bodily injury. To replace parts, call the

 

 

 

 

 

 

local sales agency.

 

Prohibited

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The equipment must be inspected every day.

14.

 

 

 

 

 

If the equipment is not inspected and maintained, errors and malfunctions may not be

 

 

 

 

 

discovered and that could result in accidents.

 

 

 

 

 

Before inspection, perform the following steps.

14.

 

 

 

 

 

(1) Turn off all input power to the inverter.

 

Mandatory

 

(2) Wait at least ten minutes and check to make sure that the charge lamp is no longer lit.

 

 

 

 

 

 

(3) Use a tester that can measure DC voltages (800VDC or more), and check to make

 

 

 

 

 

 

sure that the voltage to the DC main circuits (across PA/+ and PC/-) is 45V or less.

 

 

 

 

 

 

If inspection is performed without performing these steps first, it could lead to electric

 

 

 

 

 

 

shock.

 

5

Page 7
Image 7
Toshiba VF-FS1 instruction manual When retry function is selected inverter, Maintenance and inspection