E6581381

8.1.2Display of detailed information on a past trip

Details on a past trip (of trips 1 to 4) can be displayed, as shown in the table below, by pressing the ENT key when the trip record is selected in the status monitor mode.

Unlike the "Display of detailed trip information at the occurrence of a trip" in 8.2.2, details on a past trip can be displayed, even after the inverter is turned off or reset.

Note 10

Note 1

Note 2

Note 3

8

Note 4

Note 5

Note 8

Item displayed

Key

LED display

 

Description

operated

 

 

 

 

 

 

 

Past trip 1

 

QE

Past trip 1 (displayed alternately)

 

 

 

 

 

 

Continuous trips

ENT

P

The number of time the same trip occurred in succession is

displayed. (Unit: times)

 

 

 

 

 

 

 

 

Operation

 

Z

The operation frequency when the trip occurred is

frequency

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction of

 

HTH

The direction of rotation when the trip occurred is displayed.

rotation

 

(HTH: Forward run, HTT: Reverse run)

 

 

Operation

 

 

The operation command value when the trip occurred is

frequency

 

H

displayed.

 

 

 

command

 

 

 

 

 

 

Load current

 

E

The inverter output current when the trip occurred is

 

displayed. (%/A)

 

 

 

 

 

 

 

 

 

Input voltage

 

[

The inverter input voltage (DC) when the trip occurred is

 

displayed. (%/V).

 

 

 

 

 

 

 

 

 

Output voltage

 

R

The inverter output voltage when the trip occurred is

 

displayed. (%/V)

 

 

 

 

 

 

 

 

 

 

 

 

The ON/OFF statuses of the control input terminals (F, R,

 

 

 

RES and VIA) are displayed in bits.

 

 

 

 

 

 

 

 

 

 

ON: 

__KK

 

 

 

 

OFF: _

 

Input terminal

 

__KK

 

 

 

 

 

 

 

 

 

VIA

 

 

F

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

RES

 

 

 

 

 

 

 

 

 

The ON/OFF statuses of the control output terminals (RY

 

 

 

and FL) are displayed in bits.

 

 

 

 

 

ON: 

 

 

 

Output terminal

 

_K



_K

 

 

OFF: _

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FL

RY-RC

Cumulative

 

 

The cumulative operation time when the trip occurred is

 

V 

displayed.

 

 

 

operation time

 

 

 

 

 

 

(0.01=1 hour, 1.00=100 hours)

 

 

 

 

 

 

 

Past trip 1

MODE

QE

Press this key to return to past trip 1.

 

 

 

 

 

 

 

H-4

Page 190
Image 190
Toshiba VF-FS1 instruction manual Display of detailed information on a past trip, HtH