E6581381
8.1.2Display of detailed information on a past trip
Details on a past trip (of trips 1 to 4) can be displayed, as shown in the table below, by pressing the ENT key when the trip record is selected in the status monitor mode.
Unlike the "Display of detailed trip information at the occurrence of a trip" in 8.2.2, details on a past trip can be displayed, even after the inverter is turned off or reset.
Note 10
Note 1
Note 2
Note 3
8
Note 4
Note 5
Note 8
Item displayed | Key | LED display |
| Description | ||
operated |
| |||||
|
|
|
|
|
| |
Past trip 1 |
| QE⇔ | Past trip 1 (displayed alternately) | |||
|
|
|
|
|
| |
Continuous trips | ENT | P | The number of time the same trip occurred in succession is | |||
displayed. (Unit: times) |
|
| ||||
|
|
|
|
|
| |
Operation |
| Z | The operation frequency when the trip occurred is | |||
frequency |
| displayed. |
|
|
| |
|
|
|
|
| ||
|
|
|
|
|
| |
Direction of |
| HTH | The direction of rotation when the trip occurred is displayed. | |||
rotation |
| (HTH: Forward run, HTT: Reverse run) | ||||
|
| |||||
Operation |
|
| The operation command value when the trip occurred is | |||
frequency |
| H | displayed. |
|
|
|
command |
|
|
|
|
|
|
Load current |
| E | The inverter output current when the trip occurred is | |||
| displayed. (%/A) |
|
|
| ||
|
|
|
|
|
| |
Input voltage |
| [ | The inverter input voltage (DC) when the trip occurred is | |||
| displayed. (%/V). |
|
|
| ||
|
|
|
|
|
| |
Output voltage |
| R | The inverter output voltage when the trip occurred is | |||
| displayed. (%/V) |
|
|
| ||
|
|
|
|
|
| |
|
|
| The ON/OFF statuses of the control input terminals (F, R, | |||
|
|
| RES and VIA) are displayed in bits. | |||
|
|
|
|
|
|
|
|
|
| ON: | __KK |
| |
|
|
| OFF: _ |
| ||
Input terminal |
| __KK |
|
|
| |
|
|
|
|
| ||
| VIA |
|
| F | ||
|
|
|
|
| ||
|
|
|
|
|
| R |
|
|
|
|
|
| RES |
|
|
|
|
|
| |
|
|
| The ON/OFF statuses of the control output terminals (RY | |||
|
|
| and FL) are displayed in bits. |
|
| |
|
|
| ON: |
|
|
|
Output terminal |
| _K | _K |
| ||
| OFF: _ |
| ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| FL |
| |
Cumulative |
|
| The cumulative operation time when the trip occurred is | |||
| V | displayed. |
|
|
| |
operation time |
|
|
|
| ||
|
| (0.01=1 hour, 1.00=100 hours) |
|
| ||
|
|
|
|
| ||
Past trip 1 | MODE | QE⇔ | Press this key to return to past trip 1. | |||
|
|
|
|
|
|
|