![](/images/new-backgrounds/1300994/300994331x1.webp)
E6581381
6.20Operation panel parameter
6.20.1Prohibition of key operations and parameter settings
H : Prohibition of parameter change
H : Prohibition of frequency setting on the operation panel (FC)
H : Prohibition of panel local/remote operation (LOC/REM key)
H : Prohibition of panel operation (RUN/STOP keys)
H : Prohibition of panel emergency stop operation
H : Prohibition of panel reset operation
•Function
These parameters allow you to prohibit the operation of the RUN and STOP keys on the operation panel and the change of parameters. Using these parameters, you can also prohibit various key
6 |
| operations. |
|
| |
|
|
|
| ||
|
| [Parameter setting] |
|
| |
|
|
|
| ||
|
| Title | Function | Adjustment range | Default setting |
|
| H | Prohibition of parameter change | 0: Permitted, 1: Prohibited | 0 |
|
| H | Prohibition of frequency setting on the | 0: Permitted, 1: Prohibited | 0 |
|
|
| operation panel (FC) |
|
|
|
| H | Prohibition of panel local/remote | 0: Permitted, 1: Prohibited | 0 |
|
|
| operation (LOC/REM key) |
|
|
|
| H | Prohibition of panel operation | 0: Permitted, 1: Prohibited | 0 |
|
|
| (RUN/STOP keys) |
|
|
|
| H | Prohibition of panel emergency stop | 0: Permitted, 1: Prohibited | 0 |
|
|
| operation |
|
|
|
| H | Prohibition of panel reset operation | 0: Permitted, 1: Prohibited | 0 |
■Resetting method
Only the H parameter is designed so that its setting can be modified even if 1 (prohibited) is selected.