E6581381

4.2How to set parameters

The standard default parameters are programmed before the unit is shipped from the factory. Parameters can be divided into 5 major categories. Select the parameter to be changed or to be searched and retrieved.

Basic parameters

Extended parameters

User parameters

(automatic edit function)

Wizard function

History parameter

: The basic parameters that must be programmed

before the first use. See section 4.2.1.

 

: The parameters for detailed and special setting.

 

See section 4.2.2.

 

: Indicates parameters that are different from the

 

standard default setting parameters. Use them to

 

check after setting and to change setting.

 

(Parameter title: I4W). See section 4.2.3.

4

: The wizard function refers to the special function of

calling up ten frequently used parameters.

You can set up the inverter easily by simply setting the parameters in one after another. (Parameter name: CWH). See section 4.2.4.

:This parameter has the function of displaying, in reverse chronological order, the five parameters that were changed last. This function comes in very handy when you adjust the inverter repeatedly using the same parameter. (Parameter name: CWJ).

See section 4.2.5.

*Adjustment range of parameters

JK: An attempt has been made to assign a value that is higher than the programmable range. Or, as

a result of changing other parameters, the programmed value of the parameter that is now selected exceeds the upper limit.

NQ: An attempt has been made to assign a value that is lower than the programmable range. Or, as a result of changing other parameters, the programmed value of the parameter that is now selected exceeds the lower limit.

If the above alarm is flashing on and off, no setting can be done of values that are equal to or greater than JK or equal to or lower than NQ.

D-3

Page 57
Image 57
Toshiba VF-FS1 instruction manual How to set parameters, Basic parameters Extended parameters User parameters