E6581381
(Continued)
Error code | Failure | Description | |
code | |||
|
| ||
QER | 0026 | Overcurrent flowing in element during deceleration | |
QER | 0027 | Overcurrent flowing in element during | |
GVP | 0054 | ||
GV[R | 0029 | Inverter type error | |
QJ | 002E | External thermal input | |
G | 0032 | VIA cable break | |
G | 0033 | Communication error between CPUs | |
G | 0034 | V/F control error | |
G | 0035 | CPU fault 2 | |
UQWV | 002F |
Note: Past trip records (trip records retained or trips that occurred in the past) can be called up.
⇒See section 8.1 "Status monitor mode" for the
(*)Strictly speaking, this code is not an error code; this code is displayed to show the absence of error when the past trip monitor mode is selected.
8.2.2Display of trip information at the occurrence of a trip
| At the occurrence of a trip, the same information as that displayed in the mode described in 8.1.1, "Status monitor | |
| under normal conditions," can be displayed, as shown in the table below, if the inverter is not turned off or reset. | |
8 | To display trip information after turning off or resetting the inverter, follow the steps described in 8.1.2, "Display of | |
detailed information on a past trip." | ||
|
■Example of call-up of trip information
|
|
| Item displayed | Key | LED | Communic | Description |
|
|
| operated | display | ation No. | ||
|
|
|
|
| |||
|
|
|
|
|
|
| Status monitor mode (The code blinks if a trip |
|
|
| Cause of trip |
| QR |
| occurs.) |
|
|
|
|
|
|
| The motor coasts and comes to a stop (coast stop). |
|
|
| Parameter setting | MODE | CWH |
| The first basic parameter “CWH” (Wizard function) |
|
|
| mode |
| is displayed. | ||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| Direction of |
|
|
| The direction of rotation at the occurence of a trip |
|
|
| MODE | HTH | FE01 | is displayed. (HTH: forward run, HTT: | |
|
|
| rotation | ||||
|
|
|
|
|
| reverser run). | |
|
|
|
|
|
|
| |
|
|
| Operation |
|
|
| The operation frequency command value (Hz/free |
Note 1 |
|
|
|
| |||
| frequency |
| H | FE02 | unit) at the occurrence of a trip is displayed. | ||
|
|
|
| ||||
|
|
| command |
|
|
|
|
|
|
|
|
|
|
| The output power of the inverter at the occurrence |
Note 2 |
|
| Load current |
| E | FE03 | |
|
| of a trip (%/A) is displayed. | |||||
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The inverter input (DC) voltage (%/V) at the |
Note 3 |
| Input voltage |
| [ | FE04 | ||
|
| occurrence of a trip is displayed. | |||||
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| Output voltage |
| R | FE05 | The output voltage of the inverter at the |
|
|
|
| occurrence of a trip (%/V) is displayed. | |||
|
|
|
|
|
|
|
|
(Continued overleaf)