Toshiba VF-FS1 instruction manual Display of trip information at the occurrence of a trip

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 192
Image 192

E6581381

(Continued)

Error code

Failure

Description

code

 

 

QER

0026

Overcurrent flowing in element during deceleration

QER

0027

Overcurrent flowing in element during constant-speed operation

GVP

0054

Auto-tuning error

GV[R

0029

Inverter type error

QJ

002E

External thermal input

G

0032

VIA cable break

G

0033

Communication error between CPUs

G

0034

V/F control error

G

0035

CPU fault 2

UQWV

002F

Step-out (for PM motors only)

Note: Past trip records (trip records retained or trips that occurred in the past) can be called up.

See section 8.1 "Status monitor mode" for the call-up procedure.

(*)Strictly speaking, this code is not an error code; this code is displayed to show the absence of error when the past trip monitor mode is selected.

8.2.2Display of trip information at the occurrence of a trip

 

At the occurrence of a trip, the same information as that displayed in the mode described in 8.1.1, "Status monitor

 

under normal conditions," can be displayed, as shown in the table below, if the inverter is not turned off or reset.

8

To display trip information after turning off or resetting the inverter, follow the steps described in 8.1.2, "Display of

detailed information on a past trip."

 

Example of call-up of trip information

 

 

 

Item displayed

Key

LED

Communic

Description

 

 

 

operated

display

ation No.

 

 

 

 

 

 

 

 

 

 

 

 

Status monitor mode (The code blinks if a trip

 

 

 

Cause of trip

 

QR

 

occurs.)

 

 

 

 

 

 

 

The motor coasts and comes to a stop (coast stop).

 

 

 

Parameter setting

MODE

CWH

 

The first basic parameter “CWH” (Wizard function)

 

 

 

mode

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction of

 

 

 

The direction of rotation at the occurence of a trip

 

 

 

MODE

HTH

FE01

is displayed. (HTH: forward run, HTT:

 

 

 

rotation

 

 

 

 

 

 

reverser run).

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

The operation frequency command value (Hz/free

Note 1

 

 

 

 

 

frequency

 

H

FE02

unit) at the occurrence of a trip is displayed.

 

 

 

 

 

 

 

command

 

 

 

 

 

 

 

 

 

 

 

The output power of the inverter at the occurrence

Note 2

 

 

Load current

 

E

FE03

 

 

of a trip (%/A) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The inverter input (DC) voltage (%/V) at the

Note 3

 

Input voltage

 

[

FE04

 

 

occurrence of a trip is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output voltage

 

R

FE05

The output voltage of the inverter at the

 

 

 

 

occurrence of a trip (%/V) is displayed.

 

 

 

 

 

 

 

 

(Continued overleaf)

H-6

Page 192
Image 192
Toshiba VF-FS1 Display of trip information at the occurrence of a trip, Example of call-up of trip information