E6581381

Table of output terminal functions 3

Function

Code

Function

Action

No.

 

 

 

53

PIDFN

Inversion of signal in accordance of frequency

Inversion of PIDF setting

 

 

command (VIA)

 

54

MOFF

Undervoltage detection

ON: Undervoltage detected

 

 

 

OFF: Other than undervoltage

55

MOFFN

Inversion of undervoltage detection

Inversion of MOFF

56

LOC

Local/remote switching

ON: Local mode

 

 

 

OFF: Remote mode

57

LOCN

Inversion of local/remote switching

Inversion of LOC

58

PTC

PTC thermal alarm

ON: 60% and over the protection level by PTC

 

 

 

OFF: Normal condition

59

PTCN

Inversion of PTC thermal alarm

Inversion of PTC

60

PIDFB

Signal in accordance of frequency command (VIB)

ON: Frequency commanded by HOQF or

 

 

 

H and that by VIB show the same

 

 

 

value.

 

 

 

OFF: Frequency commanded by HOQF or

 

 

 

H and that by VIB show different

 

 

 

values.

61

PIDFBN

Inversion of signal in accordance of frequency

Inversion of PIDFB setting

 

 

command (VIB)

 

62-253

Disabled

Invalid settings, always OFF (ignored)

Invalid settings, always OFF (ignored)

254

AOFF

Always OFF

Always OFF

255

AON

Always ON

Always ON