2)Preset-speed frequency setting

Set the speed (frequency) of the number of steps necessary.

Title

Funtion

Adjustment range

Default setting

UT

Preset-speed operation frequencies 1

NN WN(Hz)

15.0

UT

Preset-speed operation frequencies 2

NN WN(Hz)

20.0

UT

Preset-speed operation frequencies 3

NN WN(Hz)

25.0

UT

Preset-speed operation frequencies 4

NN WN(Hz)

30.0

UT

Preset-speed operation frequencies 5

NN WN(Hz)

35.0

UT

Preset-speed operation frequencies 6

NN WN(Hz)

40.0

UT

Preset-speed operation frequencies 7

NN WN(Hz)

45.0

Examples of preset-speed contact input signals: Slide switch SW4 set to sink logic

 

O: ON -: OFF (Speed commands other than preset-speed commands are valid when all are OFF)

 

CC

Terminal

 

 

Preset-speed

 

 

 

 

R

1

2

3

4

5

6

7

 

 

 

 

 

RES

R-CC

{

-

{

-

{

-

{

 

 

RES-CC

-

{

{

-

-

{

{

 

 

VIA

 

 

VIA-CC

-

-

-

{

{

{

{

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+Preset-speed commands are not allocated to standard default setting. Use the input terminal function selection to allocate SS1 to SS3 terminal.

Terminal R

Input terminal function selection 2 (R)

 

H= (Preset-speed command 1: SS1)

Terminal RES

Input terminal function selection 3 (RES)

 

H= (Preset-speed command 2: SS2)

Terminal VIA

Input terminal function selection 8 (VIA)

 

H= (Preset-speed command 3: SS3)

 

Analog/contact input function selection

 

H= (VIA-contact input(Sink))

[Example of a connection diagram] (SW4 set to sink logic)

 

F (Forward run)

Forward

VIA

CC

Common

V

 

 

I

R

Preset-speed 1 (SS1)

SW3

RES

Preset-speed 2 (SS2)

 

 

VIA

Preset-speed 3 (SS3)

P24

E-29