5.5Standard default setting
V[R : Default setting
•Function
Allows setting of all parameters to the standard default setting, etc. at one time.
Note that HO, HOUN, H, H ∼ H and H will not be reset to their factory default settings.
Title | Function | Adjustment range | Default setting |
| ||
|
| 0: - |
|
|
| |
|
| 1: 50Hz default setting |
|
|
| |
|
| 2: 60Hz default setting |
|
|
| |
|
| 3: Standard default setting |
|
|
| |
|
| (Initialization) |
|
|
| |
V[R | Default setting | 4: Trip record clear | 0 |
|
| |
5: Cumulative operation time clear |
|
| ||||
5 | ||||||
|
|
|
| |||
|
| 6: Initialization of type information |
|
| ||
|
| 7: Save |
|
| ||
|
| 8: Call |
|
|
| |
|
| 9: Cumulative fan operation time |
|
|
| |
|
| record clear |
|
|
|
+This function will be displayed as 0 during reading on the right. This previous setting is displayed.
Example:
+V[R cannot be set during the inverter operating. Always stop the inverter first and then program.
Programmed value
50Hz default setting (V[R = )
Setting V[R at causes all the following parameters to be set for operation using a base frequency of 50 Hz. (This does not change the setting of any other parameters.)
Parameter HJ, WN, XN, H, H, H, H: 50Hz
Parameter H: According to model
⇒See page
50Hz default setting (V[R = )
Setting V[R at causes all the following parameters to be set for operation using a base frequency of 60 Hz. (This does not change the setting of any other parameters.)
Parameter HJ, WN, XN, H, H, H, H: 60Hz
Parameter H: According to model