Toshiba VF-FS1 instruction manual Houn

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 210
Image 210

 

 

 

 

 

 

 

 

 

 

 

 

E6581381

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

Title

Communication

Function

Unit

setting unit

 

Adjustment range

Default

User

 

Reference

 

 

 

No.

Panel/Commun

 

setting

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

 

 

 

HOUN

0005

Meter selection

-

-

0:

Output frequency

0

 

 

5.4

 

 

 

 

 

 

 

 

1:

Output current

 

 

 

 

 

 

 

 

 

 

 

 

2:

Set frequency

 

 

 

 

 

 

 

 

 

 

 

 

3:

DC voltage

 

 

 

 

 

 

 

 

 

 

 

 

4:

Output voltage command value

 

 

 

 

 

 

 

 

 

 

 

 

5:

Input power

 

 

 

 

 

 

 

 

 

 

 

 

6:

Output power

 

 

 

 

 

 

 

 

 

 

 

 

7:

Torque

 

 

 

 

 

 

 

 

 

 

 

 

8:

Torque current

 

 

 

 

 

 

 

 

 

 

 

 

9:

Motor cumulative load factor

 

 

 

 

 

 

 

 

 

 

 

 

10: Inverter cumulative load factor

 

 

 

 

 

 

 

 

 

 

 

 

11: - (do not select)

 

 

 

 

 

 

 

 

 

 

 

 

12: Frequency setting value (after

 

 

 

 

 

 

 

 

 

 

 

 

 

PID)

 

 

 

 

 

 

 

 

 

 

 

 

13: VIA Input value

 

 

 

 

 

 

 

 

 

 

 

 

14: VIB Input value

 

 

 

 

 

 

 

 

 

 

 

 

15: Fixed output 1 (Output current:

 

 

 

 

 

 

 

 

 

 

 

 

 

100%)

 

 

 

 

 

 

 

 

 

 

 

 

16: Fixed output 2 (Output current:

 

 

 

 

 

 

 

 

 

 

 

 

 

50%)

 

 

 

 

 

 

 

 

 

 

 

 

17: Fixed output 3 (Supposition

 

 

 

 

 

 

 

 

 

 

 

 

 

output at HOUN=17)

 

 

 

 

 

 

 

 

 

 

 

 

18: Serial communication data

 

 

 

 

 

 

 

 

 

 

 

 

19: For adjustments (HO set value is

 

 

 

 

 

 

 

 

 

 

 

 

 

displayed.)

 

 

 

 

 

 

 

HO

0006

Meter adjustment

-

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V[R

0007

Default setting

-

-

0: -

 

0

 

 

4.2.7

 

 

 

 

 

 

 

 

1: 50Hz default setting

 

 

 

4.2.8

 

 

 

 

 

 

 

 

2: 60Hz default setting

 

 

 

5.5

 

 

 

 

 

 

 

 

3: Default setting (Initialization)

 

 

 

 

 

 

 

 

 

 

 

 

4: Trip record clear

 

 

 

 

 

 

 

 

 

 

 

 

5: Cumulative operation time clear

 

 

 

 

 

 

 

 

 

 

 

 

6: Initialization of type information

 

 

 

 

 

 

 

 

 

 

 

 

7: Save user setting parameters

 

 

 

 

 

 

 

 

 

 

 

 

8. Call user-defined parameters

 

 

 

 

 

 

 

 

 

 

 

 

9. Cumulative fan operation time

 

 

 

 

 

 

 

 

 

 

 

 

record clear

 

 

 

 

 

 

 

HT

0008

Forward/reverse

-

-

0: Forward run

0

 

 

5.6

 

 

 

 

 

run selection

 

 

1: Reverse run

 

 

 

 

 

 

 

 

 

(Operation panel

 

 

2: Forward run (F/R switching

 

 

 

 

 

 

 

 

 

operation)

 

 

possible)

 

 

 

 

 

 

 

 

 

 

 

 

3: Reverse run (F/R switching

 

 

 

 

 

 

 

 

 

 

 

 

possible)

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0009

1

S

0.1/0.1

0.0-3200

*2

 

 

5.1.2

 

 

 

CEE

Acceleration time

 

 

 

 

 

FGE

0010

Deceleration time

S

0.1/0.1

0.0-3200

*2

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

HJ

0011

Maximum

Hz

0.1/0.01

30.0-200.0

80.0

 

 

5.7

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

WN

0012

Upper limit

Hz

0.1/0.01

0.5-HJ

50.0 (WP)

 

 

5.8

 

 

 

 

 

frequency

 

 

 

 

60.0 (WN)

 

 

 

 

 

 

NN

0013

Lower limit

Hz

0.1/0.01

0.0-WN

0.0

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

XN

0014

Base frequency 1

Hz

0.1/0.01

25.0-200.0

50.0 (WP)

 

 

5.9

 

 

 

 

 

 

 

 

 

 

60.0 (WN)

 

 

 

 

 

 

XNX

0409

Base frequency

V

1/0.1

50-330 (200V class)

*1

 

 

5.9

 

 

 

 

 

voltage 1

 

 

50-660 (400V class)

 

 

 

6.12.5

K-2

Page 210