Toshiba VF-FS1 instruction manual Acceleration/deceleration time parameters, Protection parameters

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 217
Image 217

E6581381

 

 

 

 

Minimum

 

 

 

 

Title

Communication

Function

Unit

setting unit

Adjustment range

Default

User

Reference

No.

Panel/Commun

setting

setting

 

 

 

 

ication

 

 

 

 

H

0496

Waveform switching

kHz

0.1/0. 1

0.1-14.0

14.0

 

5.10

 

 

adjustment

 

 

 

 

 

6.15.2

 

 

coefficient

 

 

 

 

 

 

*1 : Default values vary depending on the capacity. See the table of page K-14.

Acceleration/deceleration time parameters

 

 

 

 

Minimum

 

 

 

 

Title

Communication

Function

Unit

setting unit

Adjustment range

Default

User

Reference

No.

Panel/Commun

setting

setting

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

H

0500

Acceleration time

s

0.1/0.1

0.0-3200

* 1

 

6.16

 

 

2

 

 

 

 

 

 

H

0501

Deceleration time

s

0.1/0.1

0.0-3200

* 1

 

 

 

 

2

 

 

 

 

 

 

H

0502

Acceleration/decel

-

-

0: Linear

0

 

 

 

 

eration 1 pattern

 

 

1: S-pattern 1

 

 

 

H

0503

Acceleration/decel

-

-

2: S-pattern 2

0

 

 

 

 

eration 2 pattern

 

 

 

 

 

 

H

0504

Selecting an

-

-

1: Acceleration/deceleration 1

1

 

 

 

 

acceleration/decel

 

 

2: Acceleration/deceleration 2

 

 

 

 

 

eration pattern

 

 

 

 

 

 

H

0505

Acceleration/decel

Hz

0.1/0.01

0.0-WN

0.0

 

 

 

 

eration 1 and 2

 

 

 

 

 

 

 

 

switching

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

H

0506

S-pattern lower-

%

1/1

0-50

10

 

 

 

 

limit adjustment

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

H

0507

S-pattern upper-

%

1/1

0-50

10

 

 

 

 

limit adjustment

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

*1 : Default values vary depending on the capacity. See the table of page K-14.

Protection parameters

 

 

 

 

Minimum

 

 

 

 

 

 

Title

Communication

Function

Unit

setting unit

Adjustment range

Default

User

Reference

 

 

No.

Panel/Commun

setting

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

H

0601

Stall prevention

%

1/1

10-110

110

 

6.17.2

 

 

 

11

 

 

level 1

(A)

 

111 (disabled)

 

 

 

 

H

0602

Inverter trip

-

-

0: Canceled with the power off

0

 

6.17.3

 

 

 

retention selection

 

 

1: Still retained with the power off

 

 

 

 

 

H

0603

Emergency stop

-

-

0: Coast stop

0

 

6.17.4

 

 

 

 

selection

 

 

1: Slowdown stop

 

 

 

 

 

 

 

 

 

 

2: Emergency DC braking

 

 

 

 

 

H

0604

Emergency DC

s

0.1/0.1

0.0-20.0

1.0

 

 

 

 

 

 

braking time

 

 

 

 

 

 

 

 

H

0605

Output phase

-

-

0: Disabled

0

 

6.17.5

 

 

 

 

failure detection

 

 

1: At start-up (only one time after

 

 

 

 

 

 

 

mode selection

 

 

power is turned on)

 

 

 

 

 

 

 

 

 

 

2: At start-up (each time)

 

 

 

 

 

 

 

 

 

 

3: During operation

 

 

 

 

 

 

 

 

 

 

4: At start-up + during operation

 

 

 

 

 

 

 

 

 

 

5: Detection of cutoff on output side

 

 

 

 

 

H

0607

Motor 150%-

s

1/1

10-2400

300

 

6.17.1

 

 

 

 

overload time limit

 

 

 

 

 

 

 

 

H

0608

Input phase failure

-

-

0: Disabled, 1: Enabled

1

 

6.17.6

 

 

 

 

detection mode

 

 

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

 

K-9

Page 217
Image 217
Toshiba VF-FS1 instruction manual Acceleration/deceleration time parameters, Protection parameters