![](/images/new-backgrounds/1300994/300994193x1.webp)
E6581381
6. Extended parameters
Extended parameters are provided for sophisticated operation, fine adjustment and other special purposes. Modify parameter settings as required. ⇒ See section 11, table of extended parameters.
6.1Input/output parameters
6.1.1Low-speed signal
H : Low-speed signal output frequency
•Function
When the output frequency exceeds the setting of H an ON signal will be generated. This signal can be used as an electromagnetic brake excitation/release signal.
This signal can also be used as an operation signal when H is set to 0.0Hz, because an ON signal is put out if the output frequency exceeds 0.0Hz.
+ Relay output |
|
| 6 | |||
at |
|
|
| |||
[Parameter setting] |
|
|
|
|
| |
Title |
| Function | Adjustment range | Default setting |
| |
H | 0.0 ∼ HJ (Hz) | 0.0 |
|
|
Output frequency [Hz]
Set frequency |
H |
0 |
Inverted
Time [s]
ON
OFF
ON
OFF