E6581381
6.7DC braking
6.7.1DC braking
H : DC braking starting frequency
H : DC braking current
H : DC braking time
•Function
A large braking torque can be obtained by applying a direct current to the motor. These parameters set the direct current to be applied to the motor, the application time and the starting frequency.
[Parameter setting] |
|
|
|
| ||
Title | Function | Adjustment range | Default setting |
|
| |
H | DC braking starting frequency | 0.0 |
|
| ||
H | DC braking current | 50 |
| 6 | ||
H | DC braking time | 0.0- 20.0 (sec) | 1.0 |
| ||
|
Output frequency [Hz]
Set frequency
DC braking
DC braking starting frequency |
|
| |
H |
|
| |
0 | Time [s] | ||
Output current [A] | |||
|
| ||
|
| DC braking current | |
|
| H | |
0 |
|
| |
| DC braking time | H |
Operation signal (F or R)
ON OFF
Note1: During DC braking, the overload protection sensitivity of the inverter increases. The DC braking current may be adjusted automatically to prevent tripping.
Note 2: During DC braking, the carrier frequency is 6kHz irrespective of the setting of parameter H (PWM carrier frequency).