Toshiba VF-FS1 instruction manual Measures to satisfy the EMC directive

Models: VF-FS1

1 252
Download 252 pages 5.48 Kb
Page 198
Image 198

E6581381

Table 1 EMC standards

Category

Subcategory

Product

Test standard and level

standards

 

 

 

Emission

Radiation noise

 

IEC61800-3

Transmission noise

 

IEC61800-3

 

 

 

Static discharge

 

IEC61000-4-2

 

Radioactive radio-frequency

 

IEC61000-4-3

 

magnetic contactor field

IEC 61800-3

 

Immunity

First transient burst

IEC61000-4-4

 

Lightning surge

 

IEC61000-4-5

 

 

 

Radio-frequency

 

IEC61000-4-6

 

induction/transmission interference

 

 

 

Voltage dip/Interruption of power

 

IEC61000-4-11

Emission standards other than the above are applied to inverters when used in a commercial environment but not an industrial environment.

Category

Subcategory

Product

Test standard and level

standards

 

 

 

Emission

Radiation noise

IEC 61800-3

IEC61800-3

 

Transmission noise

IEC61800-3

 

 

9.1.2Measures to satisfy the EMC directive

This subsection explains what measures must be taken to satisfy the EMC directive.

(1)Insert a recommended EMI filter (Table 2) on the input side of the inverter to reduce and transmission noise and radiation noise from input cables.

In the combinations listed in Table 2, Inverters are tested in these combination to see if they comply with

9

transmission noise standards. For inverters used in Japan, it is recommended to use the NF series of noise

filters.

 

Table 2 lists noise filters recommended for the inverters.

Table 2

Combinations of inverter and EMI filter

 

 

Three-phase 200V class

 

 

 

 

Combination of inverter and filter

 

 

 

Transmission noise

Transmission noise

Inverter

EN61800-3, 1st Environment, C2

EN61800-3, 1st Environment, C1

 

Applicable filters

Length of motor

Applicable filters

Length of motor

 

connecting cable (m)

connecting cable (m)

 

 

 

VFFS1-2004PM

EMFS11-4015BZ

50

EMFS11-4015BZ

1

VFFS1-2007PM

EMFS11-4015BZ

50

EMFS11-4015BZ

1

VFFS1-2015PM

EMFS11-4015BZ

50

EMFS11-4015BZ

1

VFFS1-2022PM

EMFS11-4015BZ

50

EMFS11-4015BZ

1

VFFS1-2037PM

EMFS11-4025CZ

50

EMFS11-4025CZ

1

VFFS1-2055PM

EMFS11-4047DZ

50

EMFS11-4047DZ

1

VFFS1-2075PM

EMFS11-4047DZ

50

EMFS11-4047DZ

1

VFFS1-2110PM

EMFS11-2083EZ

50

EMFS11-2083EZ

1

VFFS1-2150PM

EMFS11-2083EZ

50

EMFS11-2083EZ

1

VFFS1-2185PM

EMFS11-2083EZ

50

EMFS11-2083EZ

1

VFFS1-2220PM

EMF3-4090F

100

EMF3-4090F

50

VFFS1-2300PM

EMF3-4180H

100

EMF3-4180H

50

I-2

Page 198
Image 198
Toshiba VF-FS1 instruction manual Measures to satisfy the EMC directive