Grindmaster AM-344-04 Programming cont, Page, Shuttle Brewers & Airpot/Shuttle Brewers

Models: AM-344-04

1 40
Download 40 pages 61.88 Kb
Page 12
Image 12
Manual background

Programming (cont.)

Settings Routine

Programming For Small: Brew Time & Pulse Brewing (refer to Table 3)

11. Press and hold both “up” and “down” arrows for 5 seconds.

12. All three “brew” lights will flash.

13. Press “Small Brew” button.

Only “Small” ready light illuminates during remaining steps. 14. Display will read “Br” (Brew Time).

15. Press “Small Brew” button to go to next setting.

16. Display will read set brew time in minutes and seconds (0.01-6.00). Default is “1.20”.

17. Press “up” or “down” arrow to change value (1 second increments). (Approximately 0.8 oz./second.)

18. Press “Small Brew” button to accept and go to next setting.

19. Display will read “P-b” (Pulse Brewing).

10.Press “Small Brew” button to accept and go to next setting.

11.Display will read “Off” or “1” – “6” (number of pulses). Default is 4.

12.Press “up” or “down” arrow to change value. (increments of 1)

13.Press “Small Brew” button to accept and go to next setting.

Note: If “Off” is selected, skip pulse timing steps.

14.Display will read “0.05” – “0.60” (pulse ON time for each pulse). Default is “0.20”.

15.Press “up” or “down” arrow to change value. (increments of 1 second)

16.Press “Small Brew” button to accept and go to next setting.

17.Display will read “0.05” – “0.60” (pulse OFF time for each pulse). Default is “0.20”.

18.Press “up” or “down” arrow to change value. (increments of 1 second)

19.Press “Small Brew” button to accept and clear display.

*During programming routine, all other brew buttons are disabled.r brew buttons are disabled.

*If ON/OFF button is pressed during programming routine, brew defaults to previous settings.

Table 3

1. PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS.

 

2. READY LIGHTS WILL FLASH.

 

 

 

 

 

3. PRESS BREW BUTTON FOR SMALL "S".

 

 

 

 

 

4. SMALL READY LIGHT FLASHES THROUGHOUT ROUTINE.

 

5. DISPLAY WILL READ AS FOLLOWS:

 

 

 

 

 

 

DISPLAY

 

 

READING ADJUST ADVANCE

 

BREW TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREW TIME (0:01-6:00)

 

 

 

 

 

 

 

 

 

 

1 minute, 20 seconds shown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULSE BREW

 

 

 

 

 

 

 

 

 

 

# OF PULSES

 

 

 

 

 

 

 

 

 

 

TO

 

(OFF, 1 - 6)

 

 

 

 

 

 

PULSE ON TIME (0:05-0:60)

 

 

 

 

 

 

 

 

 

 

# of seconds shown

 

 

 

 

 

 

 

 

 

 

PULSE OFF TIME (0:05-0:60)

 

 

 

 

 

 

 

 

 

 

# of seconds shown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 12

Shuttle Brewers & Airpot/Shuttle Brewers

Page 12
Image 12
Grindmaster AM-344-04 instruction manual Programming cont, Page, Shuttle Brewers & Airpot/Shuttle Brewers