Troubleshooting (cont.)
Filling Problems
Problem | Possible Causes | Service Check | Remedy |
|
|
|
|
Tank does not refill | • Fill valve or control | • Check to ensure proper | • If 6 pin connector is securely |
| board is faulty | connection between | attached to control board and |
|
| 6 pin connector and con- | all connections are secure |
|
| trol board. Check | and there is 24 Vac across |
|
| for proper connections | fill valve terminals, replace |
|
| at fill valve terminals. | fill valve. |
|
| Drain 1 gal. (3.8L) of |
|
|
| water from hot water |
|
|
| faucet. Check for 24 Vac |
|
|
| across fill valve |
|
|
| terminals. |
|
|
|
|
|
Heating Problems
Problem | Possible Causes | Service Check | Remedy |
|
|
|
|
Tank does not heat | • No electrical power to | • Check for proper voltage | • Establish electrical power |
| equipment | at terminal block. Check | to unit. |
|
| circuit breaker on supply |
|
|
| circuit. |
|
| • No power to control | • Check for proper voltage | • If there is not proper voltage |
| board | across transformer | across primary, proceed to step |
|
| primary terminals by | entitled “No power to control |
|
| disconnecting terminals. | board and transformer not |
|
| See wiring diagram for | powered”. If there is proper |
|
| more information. | voltage across primary, proceed |
|
|
| to step entitled “No power |
|
|
| to control board and |
|
|
| transformer powered”. |
|
|
|
|