Troubleshooting (cont.)
Heating Problems
Problem | Possible Causes | Service Check | Remedy |
|
|
|
|
Tank does not heat | • Contactor faulty. | • Ensure that coil on | • If the contactor coil is |
|
| contactor is energized | energized and there is an |
|
| by ensuring that there | open circuit across any of |
|
| is proper voltage | the contactor poles, replace |
|
| between the brown and | contactor. |
|
| white wires attached to |
|
|
| the relay. Check each |
|
|
| side of the contactor |
|
|
| (Line and Load) at each |
|
|
| pole for continuity. |
|
| • Heater faulty. | • Check resistance | • If resistance is much less than |
|
| across element(s) | 8 Ohms or much more than |
|
| with power conductors | 15 Ohms, replace heater(s). |
|
| disconnected. |
|
| • Control board is faulty. | • Check to ensure proper | • If |
|
| connection between | attached to control board |
|
| connector | and all connections are |
|
| control board. Check | secure and functioning |
|
| for proper connections | except there is not 120 Vac |
|
| in all heater control | across contactor coil terminals, |
|
| circuitry. Check for | replace control board. |
|
| proper connections |
|
|
| between N terminal of |
|
|
| contactor coil and |
|
|
| terminal block. |
|
|
|
|
|
Brewing Problems
Problem | Possible Causes | Service Check | Remedy |
|
|
|
|
Brew volume too | • Portion selected on | • Review timer settings | • Adjust timer to desired value or |
large or too small | touchpad not correct. | versus portion size. | select different portion size. |
| • Timer not set properly. | • Compare timer setting | • Adjust timer to desired value. |
|
| to either factory setting |
|
|
| or initial user setting to |
|
|
| determine if it has |
|
|
| been changed. |
|
|
|
|
|
Shuttle Brewers & Airpot/Shuttle Brewers | Page 21 |