Lennox International Inc EL280UH installation instructions Cleaning the Heat Exchanger and Burners

Models: Elite Series Gas Furnace Upflow/Horizontal Air Discharge EL280UH

1 51
Download 51 pages 39.91 Kb
Page 40
Image 40
Cleaning the Heat Exchanger and Burners

Cleaning the Heat Exchanger and Burners

NOTE − Use papers or protective covering in front of the fur- nace during cleaning.

1 − Turn off both electrical and gas power supplies to fur- nace.

2 − Remove flue pipe and top cap (some applications top cap can remain) from the unit.

3 − Label the wires from gas valve, rollout switches, prima- ry limit switch and make−up box then disconnect them.

4 − Remove the screws that secure the combustion air in- ducer/pressure switch assembly to the collector box. Carefully remove the combustion air inducer to avoid damaging blower gasket. If gasket is damaged, it must be replaced to prevent leakage.

5 − Remove the collector box located behind the combus- tion air inducer. Be careful with the collector box gas- ket. If the gasket is damaged, it must be replaced to prevent leakage.

6 − Disconnect gas supply piping. Remove the screw se- curing the burner box cover and remove cover. Re- move the four screws securing the burner manifold as- sembly to the vestibule panel and remove the assembly from the unit.

7 − Remove screws securing burner box and remove burner box.

8 − NOX units only − Remove screw securing NOX insert. Remove NOX insert. See figure 37.

 

EL280UH BURNER, COMBUSTION AIR INDUCER ASSEMBLY &

 

HEAT EXCHANGER REMOVAL

 

 

gasket

 

 

pressure switch

 

 

flue transition

 

 

collector box

Heat Exchanger

Rollout Switches

Ignitor

 

(location)

orifice plate

 

 

combustion air inducer

 

Sensor

 

 

 

 

Retention Rings

 

 

Cross Over

 

Manifold And Gas Valve

 

FIGURE 36

Page 40

Page 40
Image 40
Lennox International Inc EL280UH installation instructions Cleaning the Heat Exchanger and Burners