TABLE 14

Manifold Pressure Settings at all Altitudes

 

 

Manifold

Manifold

Manifold

Supply Line

Unit

Gas

Pressure in.wg.

Pressure in.wg.

Pressure in.wg.

Pressure

0−4500 ft.

4501−7500 ft.1

7501 − 10,000 ft.2

in. w.g.

Input

 

 

 

 

 

 

 

 

 

 

 

Low Fire

High Fire

Low Fire

High Fire

Low Fire

High Fire

Min

Max

 

 

 

 

 

 

 

 

 

 

 

Natural

1.7

3.5

1.6

3.4

1.7

3.5

4.5

13.0

070

 

 

 

 

 

 

 

 

 

LP/propane3

4.9

10.0

4.9

10.0

4.9

10.0

11.0

13.0

 

 

Natural

1.7

3.5

1.5

3.2

1.7

3.5

4.5

13.0

090

 

 

 

 

 

 

 

 

 

LP/propane3

4.9

10.0

4.9

10.0

4.9

10.0

11.0

13.0

 

 

Natural

1.7

3.5

1.5

3.2

1.7

3.5

4.5

13.0

110

 

 

 

 

 

 

 

 

 

LP/propane3

4.9

10.0

4.9

10.0

4.9

10.0

11.0

13.0

 

 

Natural

1.7

3.5

1.5

2.8

1.7

3.5

4.5

13.0

135

 

 

 

 

 

 

 

 

 

LP/propane3

4.9

10.0

4.9

10.0

4.9

10.0

11.0

13.0

 

1This is the only permissible derate for these units.

2Natural gas high altitude orifice kit required.

3A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the conversion procedure.

NOTE − Units may be installed at altitudes up to 4500 ft. above sea level without modifications.

TABLE 15

Pressure Switch and Gas Conversion Kits at all Altitudes

 

High Altitude Pressure Switch Kit

High Altitude

LP/Propane Gas Kit

LP/Propane to

Unit

Natural Gas Kit

Natural Kit

 

 

 

 

 

Input

 

 

 

 

 

 

 

0 − 4500 ft.

4501 − 7500 ft.

7501 − 10,000 ft.

7501 − 10,000 ft.

0 − 7500 ft

7501 − 10,000 ft.

0 − 7500 ft.Min

 

 

 

 

 

 

 

 

 

070

 

91W53

73W35

 

 

 

 

 

 

 

 

 

 

 

 

090

 

91W53

73W35

 

 

 

 

 

No Change

 

 

73W37

77W07

77W11

77W09

110

91W53

73W35

 

 

 

 

 

 

 

 

 

 

 

 

 

135

 

73W33

73W34

 

 

 

 

 

 

 

 

 

 

 

 

NOTE − A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the conversion procedure.