COOLING SEQUENCE OF OPERATION

POWER ON

 

 

 

YES

SIGNAL POLARITY REVERSED.

 

CONTROL WILL CONTINUE TO CALL FOR COOLING

IS POLARITY REVERSED?

 

 

IN THIS CONDITION.

 

 

 

 

STATUS ERROR CODE 5 + 4.

NO

 

 

 

NO

SIGNAL IMPROPER GROUND AT LED.

IS THERE

CONTROL WILL CONTINUE TO CALL FOR COOLING

 

PROPER GROUND?

 

IN THIS CONDITION.

 

 

STATUS ERROR CODE 5 + 3.

YES

 

 

THERMOSTAT CALLS FOR FIRST−STAGE COOL.

 

COMPRESSOR AND CONDENSER FAN

 

 

ENERGIZED.

 

 

INDOOR BLOWER ENERGIZED ON FIRST STAGE

 

COOL SPEED AFTER 2 SECOND DELAY.

 

 

 

YES

COMPRESSOR AND CONDENSER FAN DE−ENERGIZED.

FIRST−STAGE DEMAND FOR COOL SATISFIED?

INDOOR BLOWER DE−ENEGIZED.

 

 

NO

 

 

THERMOSTAT CALLS FOR SECOND−STAGE COOL.

 

INDOOR BLOWER RAMPS UP TO SECOND−STAGE COOL SPEED.

 

SECOND−STAGE DEMAND FOR COOL SATISFIED?

 

YES

 

 

UNIT RETURNS TO FIRST STAGE COOL

 

 