960 Control Troubleshooting
Alarms
The Model 960 continuously monitors itself and sounds an alarm if it detects something wrong. The alarm is a beep that is on for one second and then off for nine seconds.
When the alarm sounds, the display shows the letters “Err” with a number from 1 to 4. The table below lists the Err numbers, a description of each error, the cause of the error, and the solutions. To silence the alarm, press any button on the control. If the error still exists, the control will go back to the alarm condition after 30 seconds.
Model 960 Alarms
Indication | Description | Cause | Solution |
Err1 | Electronics Failure | Control settings need | Press any key to load default values. Refer to |
|
| reprogramming. | “Programming the Model 960 Control”. |
|
|
|
|
Err2 | Improper start of | Valve camshaft has been | Press any key to silence the alarm. (Note: |
| regeneration (limit switch | manually rotated during a | Alarm automatically clears at “TIME OF |
| closed when it should be | regeneration. | REGEN”.) |
| open). | Valve camshaft has been | The control will turn the motor on and drive |
|
| manually rotated out of | the camshaft to the proper location. |
|
| “regeneration complete” |
|
|
| position. |
|
|
| Faulty motor. | Replace the control. |
|
| Faulty motor drive. | |
|
| Replace the control. | |
|
| Faulty switch. | |
|
| Replace the control. | |
|
|
| |
|
|
|
|
Err3 | Improper finish of | Valve camshaft has been | The control will turn the motor on and drive |
| regeneration (limit switch | manually rotated out of | the camshaft to the proper location. |
| open when it should be | “regeneration complete” |
|
| closed). | position. |
|
|
| Faulty motor. | Replace the control. |
|
| Faulty motor drive. | |
|
| Replace the control. | |
|
| Faulty switch. | |
|
| Replace the control. | |
|
|
| |
|
|
|
|
Err4 | Improper control settings (one | One or more settings out of the | Hardness: Adjust range: 3 to 250. |
| or more settings out of the | allowable range. | Capacity: Adjust range: 0.1 to 140.0. |
| allowable range). |
| Refill control: Adjust range: 1 to 99. |
|
|
| Regenerant draw value: Adjust range per |
|
|
| Table 4. |
|
|
|
|
| Problem |
| Possible Cause |
| Solution |
|
|
|
|
| |
1. | Capacity display stays at 9999 | a. | Total system capacity was calculated to be | A. As the water usage continues, the remaining | |
| even through there is water |
| a value greater than 9999. |
| capacity will drop below 9999 and then other |
| usage. |
|
|
| values will be shown. |
|
|
|
|
|
|
2. | Timer beeps when left arrow | A. | Button is only active in the programming | A. | Refer to the Programming section. |
| button is pressed. |
| mode. |
|
|
|
|
|
|
| |
3. | Timer does not respond to | A. | Button is not active in the programming | A. Refer to the Regeneration section. | |
| REGEN button. |
| mode. |
|
|
|
|
|
|
|
|
4. | Timer does not display time of | A. | Transformer is unplugged. | A. | Connect power. |
| day. | B. | No electric power at outlet. | B. Repair outlet or use working outlet. | |
|
| C. | Defective transformer. | C. | Replace transformer. |
|
| D. | Defective circuit board. | D. | Replace control. |
|
|
|
|
| |
5. | Timer does not display correct | A. | Outlet operated by a switch. | A. Use outlet not controlled by switch. | |
| time of day. | B. | Power outages. | B. | Reset Time of Day. |
|
|
|
|
|
|
29