Table 8 - Performa 960 FA Level II Programming Parameters

 

Parameter

Range of Values

Minimum

Default

Units of Measure

Notes

Name

 

Description

 

Increments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P6

 

Refill controller

1 to 99

1

33

 

Must be set to 46 for Performa 960

 

 

FA operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P7

 

Regenerant draw

1 to 99

1

25

 

Select Regenerant Draw value from

 

value

 

Table 9 and enter that number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P8

 

Not used

NA

NA

NA

NA

NA

 

 

 

 

 

 

 

 

P9

 

Backwash time

3 to 30

1

14

Minutes

Skip this parameter to accept the

 

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P10

 

Slow Rinse time

8 to 125

1

40

Minutes

Skip this parameter to accept the

 

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P11

 

Fast Rinse time

2 to 19

1

4

Minutes

Skip this parameter to accept the

 

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = U.S., 1 = Metric. Skip this

P12

 

Units of measure

0 to 1

1

0

 

parameter to accept U.S. or enter 1

 

 

 

 

 

 

 

for Metric.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = 12-hour clock, 1 = 24-hour

P13

 

Clock mode

0 to 1

1

0

 

clock. Skip this parameter for a 12-

 

 

hour clock or enter 1 for a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24-hour clock.

 

 

 

 

 

 

 

 

 

 

Calendar

 

 

 

 

0 = no calendar override. Skip this

P14

 

0 to 30

1

0

Days

parameter for no calendar override

 

override

 

 

 

 

 

 

or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = variable reserve, 1 = fixed

 

 

 

 

 

 

 

reserve, 2 = variable reserve with

P15

 

Reserve type

0 to 3

1

0

 

immediate regen, 3 = fixed reserve

 

 

with immediate regen. Skip this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameter to accept the default or

 

 

 

 

 

 

 

enter a different reserve type.

 

 

 

 

 

 

 

 

 

 

Fixed reserve

 

 

 

 

Description depends on the value

 

 

 

 

 

 

entered for P15. Skip this

P16

 

capacity or initial

0 to 70

1

30

Percent of capacity

 

parameter to accept the default or

 

 

average value

 

 

 

 

enter a different value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P17

 

Operation type

0 to 2

1

2

 

2 = 5 cycle Cocurrent conditioner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = none, 1 = Regenerant Dosage/

 

 

Regen. Dosage/

 

 

 

 

Capacity change locked out. Skip

 

 

 

 

 

 

this parameter to accept the

P18

 

Capacity change

0 to 1

1

0

 

 

 

default or enter 1 to lock out

 

 

lock out

 

 

 

 

 

 

 

 

 

 

Regenerant Dosage/Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

change.

 

 

 

 

 

 

 

 

P19

 

Factory defaults

0 to 3

1

99

 

Loads in factory default values. Do

 

 

not change this parameter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Page 15