Diagnostic Error Code

FRU/Action

 

 

 

020-199-XXX

1.

Go to “Undetermined problems” on page

PCI test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

 

020-262-XXX

1.

PCI card

PCI system error

2.

Riser card, if installed

 

 

3.

System board

 

 

025-000-XXX

No action

IDE interface Test Passed

 

 

 

 

 

025-00X-XXX

1.

IDE signal cable

025-01X-XXX

2.

Check power supply voltages

IDE interface failure

3.

Reseat IDE signal cable

 

 

4.

IDE device

 

5.

System board

 

 

 

025-027-XXX

1.

IDE signal cable

IDE interface Configuration/Setup error

2.

Flash the system. See “Updating

 

 

 

(flashing) the BIOS from a disc” on page

 

 

380

 

3.

Reseat IDE signal cable

 

4.

IDE device

 

5.

System board

 

 

 

025-02X-XXX

1.

IDE signal cable

025-03X-XXX

2.

Check power supply

025-04X-XXX

3.

Reseat IDE signal cable

IDE Interface failure

 

4.

IDE device

 

5.

System board

 

 

025-195-XXX

Information only

IDE interface Test aborted by user

Re-start the test, if necessary

 

 

 

025-196-XXX

1.

Press F3 to review the log file

IDE interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

025-197-XXX

1.

Make sure the component that is called

IDE interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

66Hardware Maintenance Manual

Page 72
Image 72
Lenovo 7721 Diagnostic Error Code FRU/Action 020-199-XXX, XXX PCI card, XXX No action, XXX IDE signal cable, 025-04X-XXX