Diagnostic Error Code

FRU/Action

 

 

 

086-197-XXX

1.

Make sure the component that is called

Mouse Port interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

086-198-XXX

1.

If a component is called out, make sure

Mouse Port interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

086-199-XXX

1.

See “Undetermined problems” on page

Mouse Port interface test failed, cause

 

80

unknown

 

2.

Flash the system and re-test. See

 

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

089-000-XXX

No action

Microprocessor Test Passed

 

 

 

 

 

089-XXX-XXX

1.

Microprocessor(s)

Microprocessor failure

2.

System board

 

 

 

089-195-XXX

Information only

Microprocessor Test aborted by user

Re-start the test, if necessary

 

 

 

089-196-XXX

1.

Press F3 to review the log file

Microprocessor test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

089-197-XXX

1.

Make sure the component that is called

Microprocessor test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

089-198-XXX

1.

Flash the system. See “Updating

Microprocessor test aborted

 

(flashing) the BIOS from a disc” on

 

 

 

 

page 380

 

2.

Go to “Undetermined problems” on page

 

 

80

 

 

 

Chapter 7. Symptom-to-FRU index 71

Page 77
Image 77
Lenovo 7749 XXX If a component is called out, make sure, 086-199-XXX, XXX No action, Microprocessors, XXX Information only