Diagnostic Error Code

FRU/Action

 

 

175-195-XXX

Information only

Thermal Sensor(s) Test aborted by user

Re-start the test, if necessary

 

 

 

175-196-XXX

1.

Press F3 to review the log file

Thermal Sensor(s) test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

175-197-XXX

1.

Make sure the component that is called

Thermal Sensor(s) test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

175-198-XXX

1.

If a component is called out, make sure

Thermal Sensor(s) test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

175-199-XXX

1.

See “Undetermined problems” on page

Thermal Sensor(s) test failed, cause

 

80

unknown

 

2.

Flash the system and re-test. See

 

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

 

175-250-XXX

1.

Check fans

175-251-XXX

2.

Check Power supply voltages

Thermal Sensor(s) limit error

3.

Microprocessor

 

 

4.

System board

 

 

185-000-XXX

No action

Asset Security Test Passed

 

 

 

 

 

185-XXX-XXX

1.

Flash system

Asset Security failure

2.

System board

 

 

 

 

185-278-XXX

1.

Assure Asset Security Enabled

Asset Security Chassis Intrusion

2.

C2 Cover Switch

 

 

3.

System board

 

 

201-000-XXX

No action

System Memory Test Passed

 

 

 

 

 

201-XXX-XXX

1.

Replace the memory module called out

System Memory error

 

by the test

 

 

 

2.

System board

 

 

202-000-XXX

No action

System Cache Test Passed

 

 

 

 

 

202-XXX-XXX

1.

Cache, if removable

System Cache error

2.

System board

 

 

3.

Microprocessor

 

 

 