Lenovo 7774, 7721 030-199-XXX, XXX No action, 035-0XX-XXX RAID signal cable, XXX Information only

Models: 7610 7749 7569 7705 7611 7718 7774 7560 7799 7706 7523 7522 7717 7719 7715 7515 7773 7721

1 394
Download 394 pages 53.42 Kb
Page 74
Image 74

Diagnostic Error Code

FRU/Action

 

 

 

030-198-XXX

1.

If a component is called out, make sure

SCSI interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

030-199-XXX

1.

Go to “Undetermined problems” on page

SCSI interface test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

035-000-XXX

No action

RAID interface Test Passed

 

 

 

 

 

035-0XX-XXX

1.

RAID signal cable

RAID interface Failure

2.

RAID device

 

 

3.

RAID adapter card, if installed

 

4.

System board

 

 

035-195-XXX

Information only

RAID interface Test aborted by user

Re-start the test, if necessary

 

 

 

035-196-XXX

1.

Press F3 to review the log file

RAID interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

035-197-XXX

1.

Make sure the component that is called

RAID interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

035-198-XXX

1.

If a component is called out, make sure

RAID interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

035-199-XXX

1.

See “Undetermined problems” on page

RAID interface test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

 

68Hardware Maintenance Manual

Page 74
Image 74
Lenovo 7774, 7721, 7715, 7706 030-199-XXX, XXX No action, 035-0XX-XXX RAID signal cable, XXX Information only, 035-199-XXX