Diagnostic Error Code

FRU/Action

 

 

 

005-198-XXX

1.

If a component is called out, make sure

Video test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

005-199-XXX

1.

Go to “Undetermined problems” on page

Video test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

 

005-2XX-XXX

1.

Video card, if installed

005-3XX-XXX

2.

System board

Video subsystem error

 

 

 

 

006-000-XXX

No action

Diskette interface Test Passed

 

 

 

 

 

006-0XX-XXX

1.

Diskette drive Cable

Diskette interface error

2.

Diskette drive

 

 

3.

System board

 

 

006-195-XXX

Information only

Diskette interface Test aborted by user

Re-start the test, if necessary

 

 

 

006-196-XXX

1.

Press F3 to review the log file

Diskette interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

006-197-XXX

1.

If a component is called out, make sure

Diskette interface test warning

 

it is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

006-198-XXX

1.

If a component is called out, make sure

Diskette interface test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

006-199-XXX

1.

Go to “Undetermined problems” on page

Diskette interface test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

006-25X-XXX

1.

Diskette drive cable

Diskette interface Error

2.

Diskette drive

 

 

3.

System board

 

 

 

60Hardware Maintenance Manual

Page 66
Image 66
Lenovo 7515 005-199-XXX, 005-2XX-XXX Video card, if installed 005-3XX-XXX, XXX No action, 006-0XX-XXX Diskette drive Cable