Lenovo 7719 Diagnostic Error Code FRU/Action, Remove the game port device, Re-test the system

Models: 7610 7749 7569 7705 7611 7718 7774 7560 7799 7706 7523 7522 7717 7719 7715 7515 7773 7721

1 394
Download 394 pages 53.42 Kb
Page 76
Image 76

Diagnostic Error Code

FRU/Action

 

 

 

080-XXX-XXX

1.

Remove the game port device and

Game Port interface Error

 

re-test the system

 

 

 

 

080-195-XXX

Information only

Game Port interface Test aborted by user

Re-start the test, if necessary

 

 

 

080-196-XXX

1.

Press F3 to review the log file

Game Port interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

080-197-XXX

1.

Make sure the component that is called

Game Port interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

080-198-XXX

1.

If a component is called out, make sure

Game Port interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

080-199-XXX

1.

See “Undetermined problems” on page

Game Port interface test failed, cause

 

80

unknown

 

2.

Flash the system and re-test. See

 

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

086-000-XXX

No action

Mouse Port interface Test Passed

 

 

 

 

 

086-001-XXX

1.

Mouse

Mouse Port interface Presence

2.

System board

 

 

 

 

086-032-XXX

1.

Mouse

Mouse Port interface Device controller

2.

System board

failure

 

 

 

 

 

086-035-XXX

1.

Mouse

Mouse Port interface Reset

2.

System board

 

 

 

 

086-040-XXX

1.

Run Setup

Mouse Port interface IRQ failure

2.

Mouse

 

 

3.

System board

 

 

086-195-XXX

Information only

Mouse Port interface Test aborted by user

Re-start the test, if necessary

 

 

 

086-196-XXX

1.

Press F3 to review the log file

Mouse Port interface test halt, error

2.

Re-start the test to reset the log file

threshold exceeded

 

 

 

 

 