Lenovo 7610 XXX Make sure the component that is called, 015-199-XXX, XXX No action, XXX PCI card

Models: 7610 7749 7569 7705 7611 7718 7774 7560 7799 7706 7523 7522 7717 7719 7715 7515 7773 7721

1 394
Download 394 pages 53.42 Kb
Page 70
Image 70

Diagnostic Error Code

FRU/Action

 

 

 

015-196-XXX

1.

Press F3 to review the log file

USB port test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

015-197-XXX

1.

Make sure the component that is called

USB port test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

015-198-XXX

1.

If a component is called out, make sure

USB port test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

015-199-XXX

1.

Go to “Undetermined problems” on page

USB port test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

018-000-XXX

No action

PCI Card Test Passed

 

 

 

 

 

018-0XX-XXX

1.

Riser card, if installed

PCI Card Failure

2.

System board

 

 

 

 

018-195-XXX

1.

PCI card

PCI Card Test aborted by user

2.

Information only

 

 

 

Re-start the test, if necessary

 

 

 

018-196-XXX

1.

Press F3 to review the log file

PCI Card test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

018-197-XXX

1.

Make sure the component that is called

PCI Card test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

64Hardware Maintenance Manual