Lenovo 7799 Diagnostic Error Code FRU/Action 089-199-XXX, XXX No action, 170-0XX-XXX Flash system

Models: 7610 7749 7569 7705 7611 7718 7774 7560 7799 7706 7523 7522 7717 7719 7715 7515 7773 7721

1 394
Download 394 pages 53.42 Kb
Page 78
Image 78

Diagnostic Error Code

FRU/Action

 

 

 

089-199-XXX

1.

See “Undetermined problems” on page

Microprocessor test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

170-000-XXX

No action

Voltage Sensor(s) Test Passed

 

 

 

 

 

170-0XX-XXX

1.

Flash system

Voltage Sensor(s) failure

2.

System board

 

 

 

170-195-XXX

Information only

Voltage Sensor(s) Test aborted by user

Re-start the test, if necessary

 

 

 

170-196-XXX

1.

Press F3 to review the log file

Voltage Sensor(s) test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

170-197-XXX

1.

Make sure the component that is called

Voltage Sensor(s) test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

170-198-XXX

1.

If a component is called out, make sure

Voltage Sensor(s) test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Go to “Undetermined problems” on page

 

 

80

 

 

 

170-199-XXX

1.

See “Undetermined problems” on page

Voltage Sensor(s) test failed, cause unknown

 

80

 

 

 

2.

Flash the system and re-test. See

 

 

“Updating (flashing) the BIOS from a

 

 

disc” on page 380

 

3.

Replace component under function test

 

 

 

170-250-XXX

1.

Power supply

170-251-XXX

2.

System board

Voltage Sensor(s) Voltage limit error

 

 

 

 

 

170-254-XXX

1.

Voltage Regulator Module (VRM)

Voltage Sensor(s) Voltage Regulator Module

2.

Microprocessor

error

3.

System board

 

 

 

175-000-XXX

No action

Thermal Sensor(s) Test Passed

 

 

 

 

 

175-0XX-XXX

1.

Flash system

Thermal Sensor(s) failure

2.

System board

 

 

 

 

72Hardware Maintenance Manual

Page 78
Image 78
Lenovo 7799 Diagnostic Error Code FRU/Action 089-199-XXX, XXX No action, 170-0XX-XXX Flash system, XXX Information only