Diagnostic Error Code

FRU/Action

 

 

206-000-XXX

No action

Diskette Drive Test Passed

 

 

 

 

 

206-XXX-XXX

1.

Diskette Drive Cable

Diskette Drive error

2.

Check power supply voltages

 

 

3.

Diskette drive

 

4.

System board

 

 

215-000-XXX

No action

CD-ROM Drive Test Passed

 

 

 

 

 

215-XXX-XXX

1.

CD-ROM Drive Cable

CD-ROM Drive error

2.

Check power supply voltages

 

 

3.

CD-ROM drive

 

4.

System board

 

 

217-000-XXX

No action

Hard Disk Drive Test Passed

 

 

 

 

 

217-25X-XXX

1.

Hard Disk Drive Cable

217-26X-XXX

2.

Check power supply voltages

Hard Disk Drive (IDE) error

3.

Reseat the hard disk drive cable

 

 

4.

Hard Disk drive (IDE)

 

5.

System board

 

 

 

217-28X-XXX

1.

Hard Disk Drive Cable

217-29X-XXX

2.

Check power supply voltages

Hard Disk Drive (SCSI) error

3.

Reseat the hard disk drive cable

 

 

4.

Hard Disk drive (SCSI)

 

5.

SCSI adapter card

 

6.

System board

 

 

220-000-XXX

No action

Hi-Capacity Cartridge Drive Test Passed

 

 

 

 

 

220-XXX-XXX

1.

Remove the Hi-Capacity Cartridge

Hi-Capacity Cartridge Drive error

 

Drive and re-test the system

 

 

 

 

 

301-XXX-XXX

1.

Keyboard

Keyboard error

2.

Check and test mouse

 

 

3.

System board

 

 

301-000-XXX

No action

Keyboard Test Passed

 

 

 

 

302-000-XXX

No action

Mouse Test Passed

 

 

 

 

 

302-XXX-XXX

1.

Mouse

Mouse error

2.

Check and test Keyboard

 

 

3.

System board

 

 

303-000-XXX

No action

Joystick Test Passed

 

 

 

 

303-XXX-XXX

Remove the Joystick and re-test the system

Joystick error

 

 

 

 

305-000-XXX

No action

Monitor DDC Test Passed

 

 

 

 

 

74Hardware Maintenance Manual

Page 80
Image 80
Lenovo 7705 Diskette Drive error, Check power supply voltages, Diskette drive, XXX No action CD-ROM Drive Test Passed