GE 960 Series manual Level II Programming Parameters, Name, Default

Models: 960 Series

1 32
Download 32 pages 856 b
Page 9
Image 9
Table 3 - Level II Programming Parameters

Table 3 - Level II Programming Parameters

Parameter

 

 

 

 

 

 

 

 

 

 

 

 

Name

Description

Range of Values

Minimum

Default

Units of

Notes

Increments

Measure

 

 

 

 

 

 

 

 

 

 

 

 

P6

Refill controller

1 to 99

1

33

 

Enter the value molded into the

 

end of the refill controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

P7

Regenerant

1 to 99

1

25

 

Select number from Table 4 and

draw value

 

enter that number.

 

 

 

 

 

 

 

 

 

 

 

 

P8

Not used

NA

NA

NA

NA

NA

P9

Backwash time

3 to 30

1

14

Minutes

Skip this parameter to accept the

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

P10

Slow rinse time

8 to 125

1

40

Minutes

Skip this parameter to accept the

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

P11

Fast rinse time

2 to 19

1

4

Minutes

Skip this parameter to accept the

default or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = U.S., 1 = metric. Skip this

P12

Units of Measure

0 to 1

1

0

 

parameter to accept U.S. or enter

 

 

 

 

 

 

1 for metric.

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = 12-hour clock.

P13

Clock mode

0 to 1

1

0

 

1 = 24-hour clock. Skip this

 

parameter for a 12-hour clock or

 

 

 

 

 

 

 

 

 

 

 

 

enter 1 for a 24-hour clock.

 

 

 

 

 

 

 

 

Calendar

 

 

 

 

0 = no calendar override. Skip this

P14

0 to 30

1

0

Days

parameter for no calendar

override

 

 

 

 

 

override or enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = variable reserve, 1 = fixed

 

 

 

 

 

 

reserve, 2 = variable reserve with

 

 

 

 

 

 

immediate regen,

P15

Reserve type

0 to 3

1

0

 

3 = fixed reserve with immediate

 

 

 

 

 

 

regen. Skip this parameter to

 

 

 

 

 

 

accept the default or enter a

 

 

 

 

 

 

different reserve type.

 

 

 

 

 

 

 

 

Fixed reserve

 

 

 

 

Description depends on the value

 

 

 

 

Percent of

entered for P15. Skip this

P16

capacity or initial

0 to 70

1

30

capacity

parameter to accept the default or

 

average value

 

 

 

 

 

 

 

 

enter a different value.

 

 

 

 

 

 

 

 

 

 

 

 

 

P17

Operation type

0 to 2

1

2

 

2 = 5-cycle

 

cocurrent conditioner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = none, 1 = salt/capacity change

P18

Salt/capacity

0 to 1

1

0

 

locked out. Skip this parameter to

change lockout

 

accept the default or enter 1 to

 

 

 

 

 

 

 

 

 

 

 

lock out salt/capacity change.

 

 

 

 

 

 

 

 

 

 

 

 

 

Loads in a set of default values.

P19

Factory defaults

 

1

99

 

Refer to the Special Notes for

 

 

Level II Parameters section in this

 

 

 

 

 

 

 

 

 

 

 

 

manual. Do Not Change.

 

 

 

 

 

 

 

9

Page 9
Image 9
GE 960 Series manual Level II Programming Parameters, Name, Default