GE 960 Series manual Level II Parameters Table, Special Notes for Level II Parameters

Models: 960 Series

1 32
Download 32 pages 856 b
Page 8
Image 8
Level II Parameters (Table 3)

Table 2 - Suggested Salt Dial Settings (Pounds of Salt) For Various Size Softeners - P1 through P5

Capacity Setting

0.5 Ft3

0.75 Ft3

1.0 Ft3

1.25 Ft3

1.5 Ft3

1.75 Ft3

2.0 Ft3

2.5 Ft3

(Kilograins)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

4.6

 

 

 

 

 

 

 

 

 

16

9.0

5.6

 

 

 

 

 

 

 

 

 

20

8.6

6.0

 

 

 

 

 

 

 

 

 

24

14.0

8.6

7.0

 

 

 

 

 

 

 

 

 

30

15.0

11.0

9.0

 

 

 

 

 

 

 

 

 

32

18.6

12.6

10.0

9.0

 

 

 

 

 

 

 

 

 

35

16.0

12.0

10.0

9.0

 

 

 

 

 

 

 

 

 

40

23.0

17.0

14.0

12.0

 

 

 

 

 

 

 

 

 

48

28.0

21.0

17.0

14.0

 

 

 

 

 

 

 

 

 

60

30.0

21.0

 

 

 

 

 

 

 

 

 

Level II Parameters (Table 3)

The Level II Parameters are P6 through P19 in Table 3. The Home Owner Manual for this product does not mention these parameters, so the end user does not normally have access to these values. To access Level II Parameters, simultaneously press and hold the down arrow () and up arrow () buttons for three seconds.

If the control was alternating between Time of Day and Capacity when the above button sequence is entered, the display shows P1. If a different Level I Parameter was displayed, the display shows the “P” number for that parameter. Refer to Table 3 to find the “P” number associated with each parameter. Use the up arrow () button or the down arrow () button to move from one parameter to the next. The display cycles through the “P” numbers shown in Table 1 and Table 3. When you reach P19, the next P number will go back to P1.

When the parameter number you want to change is on the display, press the left arrow () button to display the data assigned to that parameter. Press the SET button and the far right number on the display starts flashing. If you want to change this number, press the up arrow () button or the down arrow () button. To skip the number without changing, press the left arrow () button. When the number is correct, press the SET button. The numbers stop flashing and the control accepts the new setting. If a beep sounds, the new setting was not accepted. Refer to Table 3 for allowable values for that parameter.

To change or view other parameters, press the left arrow () button to have the display show “P” numbers. Now use the up arrow () button or the down arrow () button to move to the parameter number you wish to change.

To exit the Level II programming mode, simultaneously press and hold the down arrow () and up arrow () buttons for three seconds, or wait 30 seconds without pressing a button. The control starts alternating the display between Time of Day and Capacity.

Special Notes for Level II Parameters

The programming parameters in Level II can be used to increase the efficiency of this conditioner. Especially note the regenerant Draw Value parameter. This was set at the factory to meet the needs of a system with low water pressure. If an installation has higher water pressure or uses a large injector the efficiency of the system can be improved by changing P6 and P7.

Refill Control Value

The Refill control valve must be set to 33. The valve is molded into the end of the refill control as shown in Figure 7. Verify that the setting is 33 and move on to the next parameter.

Figure 7 - Refill Control

8

Page 8
Image 8
GE 960 Series manual Level II Parameters Table, Special Notes for Level II Parameters, Refill Control Value