Troubleshooting (cont.)
Brewing Problems
Problem | Possible Causes | Service Check | Remedy |
|
|
|
|
Brew cycle will | • Controller faulty. | • Check to see that the | • If there is not 24 Vac across |
not start |
| power is supplied to the | brew valve, replace control |
|
| controller by following | board. |
|
| instructions given in |
|
|
| the Troubleshooting |
|
|
| section on Filling |
|
|
| Problems. Once |
|
|
| touchpad and momentary |
|
|
| switch integrity is |
|
|
| assured (see above), |
|
|
| initiate a brew cycle |
|
|
| and check for 24 Vac |
|
|
| across brew valve. |
|
|
|
|
|
Sprayhead will not | • Brew valve not closing | • Visually inspect brew | • Clean lime from valve. Seat, |
stop dripping water | completely. | valve at hose | cup or entire valve may need |
|
| connections. | replacement. |
| • Water in tank boiling. | • Remove sprayhead | • Reduce tank temperature. |
|
| and determine if drip is |
|
|
| coming from overflow. |
|
|
|
|
|
If you still need help, call our Service Department at (800)
Prior authorization must be obtained from Grindmaster Corporation’s Technical Services Department for all warranty claims.
Shuttle Brewers & Airpot/Shuttle Brewers | Page 23 |