Grindmaster AM-344-04 Troubleshooting, Error Messages, Filling Problems, Possible Causes, Remedy

Models: AM-344-04

1 40
Download 40 pages 61.88 Kb
Page 17
Image 17
Troubleshooting

Troubleshooting

The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in the order shown until the exact nature of the problem is determined.

The following procedures must be performed by a qualified service technician. Disconnect power to machine before servicing.

Error Messages

Problem

Possible Causes

Service Check

Remedy

 

 

 

 

ER1

• Fill valve on for over

• Check system for

• Correct any leaks and reset

 

6 min. (This occurs

water leaks.

controller.

 

during initial fill on some

 

 

 

units – see Initial

 

 

 

Start-up.)

 

 

 

 

 

 

ER2

• Thermistor failure or

• Ensure that connector

• Secure connections and reset

 

loose connections in

is securely attached to

controller. If error reoccurs,

 

thermistor circuit.

controller and that

replace thermistor.

 

 

thermistor is securely

 

 

 

connected.

 

 

 

 

 

ER3

• Thermistor is reading

• Check tank

• Replace thermistor.

 

out of range.

temperature.

 

 

 

 

 

ER4

• No heat is detected

• See Heating Problems

• See Heating Problems

 

 

 

 

Filling Problems

Problem

Possible Causes

Service Check

Remedy

 

 

 

 

Overfilling water

• Fill valve not sealing

• Check to see if water

• Disassemble valve and clean

tank when power

properly.

enters tank continuously

out debris. Valve may need to

is Off

 

(usually at a slow rate).

be replaced.

 

 

 

 

 

 

 

Overfilling water

• High electrode coated

• Disconnect electrode

• Remove electrode assembly

tank only when

with lime or faulty.

wire at quick connect

and clean the probes. If

power is On

 

(brown wire). Connect a

problem is not corrected,

 

wire from the quick con-

replace electrode assembly.

 

 

 

 

nect to the cabinet body.

 

 

 

If filling stops, this is the

 

 

 

error cause.

 

 

• Connection from

• Check to ensure

• Make connection to tank

 

control board to tank

connection (red

secure.

 

body faulty.

wire) is secure.

 

 

• Control board is faulty.

• Secure connection from

• Replace control board.

 

 

control board to metal

 

 

 

enclosure does not

 

 

 

stop filling.

 

 

 

 

 

Shuttle Brewers & Airpot/Shuttle Brewers

Page 17

Page 17
Image 17
Grindmaster AM-344-04 Troubleshooting, Error Messages, Filling Problems, Possible Causes, Service Check, Remedy